WARNING:
Do not allow familiarity with products to make you care-
less. Remember that a careless fraction of a second is
sufficient to inflict serious injury.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes resulting in possible
serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
APPLICATIONS
You may use this product for the following purposes:
„ Charging 6 and 12 Volt lead acid batteries.
CAUTION:
If at any point during the charging process none of the
LEDs are lit, remove the battery charging cable from
the battery and disconnect the AC power cord from the
power source to avoid damaging the product. DO NOT
connect the battery maintainer to another battery. Return
the maintainer and battery to your nearest service center
for service or replacement.
CAUTION:
Charge in a well-ventilated area. Do not block maintainer
vents. Keep them clear to allow proper ventilation.
WARNING:
Use the battery maintainer to charge 6 and 12 Volt lead
acid batteries only. Other types of batteries may burst,
causing personal injury and damage.
CHARGE TIME
The charge time is approximate and will depend on the type
of battery and discharge state. Always follow the battery
manufacturer's specific charging instructions.
„ Test the battery for state of charge with a hydrometer or
electric percent-of-charge tester.
OPERATION
„ Determine the size of the battery in Amp Hour (Ah)
or Reserve Capacity. If the ratings are not printed on
the battery, contact your local battery dealer for this
information before charging.
NOTE: These are the only ratings that can be used to
determine the charge time.
„ Use the battery rating, the charge level of the battery,
and the amp setting to be used on the charger in the
following formula:
Amp Hour Rating of Battery
x Percent of Charge Needed
Amp Setting Selected on
the battery maintainer
„ If the battery is rated in Reserve Capacity, use the
following formula to convert reserve capacity to Amp
Hours (Ah):
Reserve Capacity
VOLTAGE SELECTOR BUTTON
See Figure 3.
The battery maintainer can charge both 6 Volt and 12 Volt
vented wet lead acid batteries. The amount of voltage pro-
vided by the maintainer is controlled by the voltage selector
button. To change the voltage, press the button to select the
voltage indicated by a green LED.
CONNECTING AND DISCONNECTING THE
BATTERY MAINTAINER TO THE BATTERY
See Figure 4.
WARNING:
Before using the battery maintainer, follow all safety and
connection instructions. Failure to do so can damage
the battery and cause serious personal injury or death.
If necessary, remove the battery from the vehicle to charge.
Always remove the grounded terminal first. Make sure all
accessories in the vehicle are off. Place the charger on a dry,
non-flammable surface. Follow Specific Safety Instructions
outlined on page 3.
To connect:
„ Using the battery clamps, connect the red wire to the
positive (+) terminal first, then connect the black wire to the
negative (-) terminal. Make sure all connections are secure.
NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.
NOTE: Never start a vehicle if the maintainer is attached to
the vehicle battery.
7 — English
x 1.3 = Hours Needed to Charge
x 15.6 = Amp Hour (Ah) Rating
2