The zone must be completely within the
mowing area of the boundary cable
•
The distance from the zone wire
boundary wire
•
The zone should not cover the guide
(7)
wire
, otherwise the robotic lawnmower
may not find the charging station. If you
do not remember where the guide wire is,
start the robotic lawnmower at the end
of the guide cable and let it return to the
charging station (see Operator's manual
of the robotic lawnmower).
•
The distance from zone wire
(7)
wire
should be at least 60 cm.
•
The ZoneProtect and all objects inside
must be at least 35 cm inside the zone
[ Fig. I3 ].
•
Do not lay the cable on slopes > 10 %.
•
When using several ZoneProtects, the
distance from zone wire to zone wire
must be at least 60 cm.
•
The zone cable must not cross [ Fig. I4 ].
•
The maximum length of the zone wire
is 15 m.
To connect the zone cable [ Fig. I1 / I2 ]:
(2)
The zone cable
, the ground hooks
the connection clamps
the scope of delivery.
1. Place the zone cable
zone.
2. Cut both ends of the zone cable
length at the point where you want to set
up the ZoneProtect.
3. Attach one connection clamp
end of the zone cable
14
GAR_15021-20.960.05_2024-04-30.indd 14
GAR_15021-20.960.05_2024-04-30.indd 14
(6)
.
(2)
to the
(6)
must be at least 60 cm.
(2)
to guide
(3)
and
(4)
are not included in
(2)
around the desired
(2)
to
(4)
to each
(2)
.
4. Attach the connection clamps
(5)
connections
of the ZoneProtect.
5. Secure the ZoneProtect and the zone cable
with the ground hooks
6. Activate the Zone Generator option in
your robotic lawnmower (see Operator's
manual of the robotic lawnmower).
To test the installation:
1. Set the product to ON and make sure that
the LED indicator is green.
2. Make sure that ECO mode of the robotic
lawn mower is disabled.
Refer to ECO Mode in the Operator's
Manual for the robotic lawnmower.
3. Put the robotic lawn mower 1 – 2 m in front
of the stay-out zone. Make sure that the
robotic lawnmower points forward to the
stay-out zone.
4. Start the robotic lawnmower and make sure
that it stops by the zone boundary wire.
If it enters the stay-out zone, check the con-
ditions for the installation.
3. OPERATION
To charge the battery [ Fig. O1 / O2 ]:
The 5 V power supply unit with USB-A socket
is not included.
The battery is delivered partially charged.
To ensure the full performance of the battery,
fully charge the battery before the first use.
The ZoneProtect cannot be used during
charging.
(4)
to the
(3)
.
30.04.24 09:52