6 Putting into operation

6.1 Attaching the CAT3 to the robot

1
14
13
1
Torch
2
Torch mount
3
Dowel screw 8 H7
4
Helix cable
5
CAT3
Fig. 7
Attaching the CAT3 to the robot
NOTICE
• Before attaching the CAT3 (5), first move the robot (7) into the maintenance position.
• To fasten the CAT3 (5) to the robot (7), a distance flange (6) is required. This must
correspond to the hole patterns of the CAT3 (5) and the robot (7).
• To fasten the torch (1) to the CAT3 (5), a torch mount (2) is required. This mount depends
on the type of torch.
1 Use the cylinder head screw (8) to attach the distance flange (6) to the robot (7).
2 Use cylinder head screws (9) to attach the CAT3 (5) to the distance flange (6).
3 Use the clamping ring (12) and cylinder head screw (13) to attach the bracket (11)
to the CAT3 (5).
4 Use the dowel screw (3) and nut (14) to attach the torch mount (2) to the bracket (11).
EN - 14
2
3
12
11
10
6
Distance flange
7
Robot
8
Cylinder head screw
9
Cylinder head screw M4x55 (6 pcs)
10 Feather key
4
5
9
8
11 Bracket
12 Clamping ring
13 Cylinder head screw M8
14 Nut M8 with washer