D1
4
SAFETY DEVICES
•
SMOKE EXTRACTOR BREAKDOWN
If the extractor stops, the electronic card automatically blocks the fuel supply.
•
BREAKDOWN OF THE FUEL LOADING MOTOR
If the geared motor stops, the stove or insert keeps on working (only the smoke extractor) until the minimum working smoke temperature goes
down and stops.
•
TEMPORAL POWER LOSS
After a short power loss, the equipment will restart automatically. However in the event of a lack of electricity the stove may give off a small
amount of smoke inside the room for a period of approximately 3-5 minutes. THIS DOES NOT ENTAIL ANY HEALTH RISK. This is a reason
why Bronpi advises, whenever possible, to connect the primary air inlet pipe to the exterior of the house in order to assure that the stove does
not give off smokes after a short power loss.In the model Neva it is not possible to connect the air intake duct with the outside because of the
air intake comes directly from the front of the insert.
•
ELECTRICAL PROTECTION
The stove is protected against abrupt electricity oscillations through a general fuse placed in the back part. (4A250V
Retarded) (See drawing D3).
• SMOKE OUTLET PROTECTION
The electronic pressure switch blocks the operation of the stove in the event of an abrupt change
of the pressure inside the combustion chamber (door opening, breakdown of the smoke extraction
motor, smoke returns, etc). If this happens, the stove will go into an alarm state (see drawing D4).
• PROTECTION IN THE EVENT OF HIGH TEMPERATURE OF PELLET (80ºC)
In the event of overheating of the internal part of the tank, this device blocks
the operation of the machine. The restart needs to be done manually by an
D4
authorised technician (see drawing D5).
The restoration of the 80ºC safety device is not included in the warranty unless
the technical assistance centre can demonstrate a faulty component.
•
FLOW SENSOR (OASYS TECHNOLOGY).
Your stove or insert has a flow sensor (see drawing D6) placed inside the primary air suction pipe that
detects the proper circulation of combustion air and the smoke exhaust. In case of insufficient air inlet (due to
incorrect smoke outlet or improper air intake), the sensor sends a "block" signal to the stove.
The OASYS TECHNOLOGY (Optimum Air System) allows a constant combustion by controlling automatically
the draft according to the characteristics of the flue (curves, length, diameter, etc) and the environmental
conditions (wind, humidity, atmospheric pressure, etc). To that end, the fitter must enter in the technical menu the
geographical altitude of the equipment installation place.
5
INSTALLATION REQUIREMENTS
The way of installing the stove or insert will affect the safety and the proper operation. For this reason, it is recommendable that the installation
is carried out by people who are qualified and informed about the compliance with the installation and safety norms.
If your equipment is not properly installed, it may cause serious damage.
Before the installation, follow the next verifications:
•
Make sure that the floor can sustain the weight of the equipment and make a proper isolation in the case that it is made of flammable
material (wood) or a material that can be affected by a thermal shock (plaster cast, for example).
•
If the equipment is installed on a floor which is not completely refractory or inflammable such as parquet, carpet, etc, it is necessary to
replace this part or introduce a fire-resistant base so that it protrudes out the oven 30 cm. Example of materials include steel flooring,
glass base or any other type of fire-resistant material.
•
Make sure that there is proper ventilation in the place where it is installed (air intake).
•
Avoid the installation in places where there are collective ventilation pipes, hoods with or without extractor, B type gas equipments,
heat pumps or equipments that can cause that the draw is not good if they are used at the same time.
•
Make sure that the smoke duct and the pipes used for the chimney are suitable for the operation of the insert.
•
Make sure that every equipment has their own smoke duct. Do not use the same duct for several equipments.
We recommend that you call your fitter in order to check both the chimney as well as the air flow for the combustion.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
26
D2
D3
D5
D6
RADIOFREQUENCY SERIES