Menú 01
VENT-2
1
VENT-3
2
D31
-
Air to the front side. Press the control to the rear.
-
Air to the channelling outputs. Press the control forward. Due to safety reasons, a part of the flow will
come out for the front side of the insert.
-
Air to both outputs, front and rear. Place the control to the desired flow regulation.
NOTE: because of the high temperatures reached on this zone, the glove must be used in order to
operate the control or otherwise the provided hook (cold hands handle) by entering the end of the
hook on the control hole.
8
SERVICING AND CARE
The maintenance operations guarantee a proper working of the product over
its lifetime. Not making these maintenance operations will affect the security
of the product.
8.1
BURNER CLEANING
The burner cleaning must be made daily (see drawing D33).
•
Remove the burner from its place and clean the holes.
•
Use a vacuum to get rid of the ashes in the burner. You can buy
a Bronpi vacuum-cleaner in the same Bronpi distributor where you
bought your stove.
8.2
SCRAPER'S USE (IN THE MODELS THAT INCORPORATE IT)
The smoke chamber cleaning allows that the thermal power is constant during a long time. This operation
must be made at least once a day. To do it just use the scrapers placed on the top of the stove, by moving
them up to down and vice versa several times (see drawing D34).
NOTE: The model Neva has not these scrapers.
The model Damasco is provided with two kind of scrapers: those that are placed on the front of the insert,
which movement is horizontal, forward and backward movement (see drawing D35) and the scrapers placed
on the top of the equipment with a vertical movement, up to down (see drawing D36). In order to access to
these seconds scrapers it is necessary to extract the mobile part of the insert by using the guides. This second cleaning must be made when
the insert is turned off and cold.
D35
8.3
CLEANING THE ASH PAN
The ash pan should be emptied when necessary. The stove should not be operated
without having the ash pan inside (see drawing D37).
The model Damasco is provided with two ash pans, one on each side of the burner
(see drawing D38).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
7.4
MODEL DAMASCO
The model Damasco includes on the rear top side two outputs with a 80 mm diameter corresponding to
the forced air output channelling system to heat other adjacent or upper rooms. The flow of these outputs
must be regulated by the operation of a control placed on the front of the insert, on the upper central side.
This model is provided with two tangential turbines. The main fan (tangential double turbine) always
addresses the whole air flow to the frontal exit of the equipment and the second turbine can address the
flow to the frontal or to the channelling. Its operation is related to the
working power of the insert.
With this handle we can change the air flow in the following way (see
drawing D32).
D36
D37
33
D32
D33
D34
D38
RADIOFREQUENCY SERIES