PUMP
IDENTIFICATION
(Not all model combinations are available
Consult your Suntec representative)
Pressure regulation
Gear set capacity
(see pump capacity curves)
Shaft rotation
and nozzle location
(seen from shaft end)
(vista lato albero)
A : clockwise rotation/
right hand nozzle.
C: anti clockwise rotation/
left hand nozzle. izquierdo
E
4
N
C
1
069
Flange mounting
body with
069 :
preheater cavity
model without cut-off function
Revision number
Installation
P : by-pass plug installed in return port
for two-pipe operation
TECHNICAL DATA
General
Mounting
Flange mounting according to EN 225.
Connection threads
Cylindrical according to ISO 228/1
Inlet and return
G 1/2"
Nozzle outlet
G 1/4"
Pressure gauge port
G 1/8"
Vacuum gauge port
G 1/2"
Valve function
Pressure regulating - no cut-off
Filter
Open area: 45 cm
Opening size
Shaft
Ø 11mm according to EN 225.
By-pass plug
Inserted in return port for 2 pipe system
to be removed with a 3/16" Allen key
for 1 pipe system
Weight
4
kg
Hydraulic data
Nozzle pressure range
14 - 30 bar
Delivery pressure setting
20 bar
Operating viscosity
3 - 75 cSt
Oil temperature
0 - 130°C max. nella pompa
installation to light oil :
I
nlet pressure
vacuum to prevent air separation from oil.
installation to heavy oil : 3,5 bar m
Return pressure
installation to light oil : 3,5 bar max.
installation to heavy oil : 3,5 bar max.
Rated speed
3600 gpm max.
Torque (to 40 gpm)
0,3 N.m
Choice of heater
Crtridge
Ø 12 mm
Fitting
in accordo con EN 50262
Rating
50-80 W
PUMP SUNTEC E TECHNICAL DATA
Oil under suction
Oil under pressure
By-passed oil
returned to tank,
or to suction
Filter
TWO PIPE
INSTALLATION
7 P
²
;
.
0,45 bars max.
a
x.
- 19 -
420010310103 OILFLAM 80.1÷200.1 PR
Inlet
Tenuta
albero
Pressure
adjustment
By-pass
gauge port
plug
inserted
Back
Return
to suction
By-pass
plug
removed
ONE PIPE
Return
INSTALLATION
plugged
Pump capacity
Capacity (L/h)
Capacity (L/h)
Viscosity
=
200 cSt
20 cSt
Rated speed
5 cS
Data shown take into account a wear margin.
Do not oversize the pump when selecting the
gear capacity.
Vacuum
gauge port
Gear set
By-pass hole
To nozzle
Pressure
Pressure (bar)
Pressure (bar)
gpm
= 2850