4.6.1
Electrical wiring on burners with 6 pin plug-
socket
The gas trains shown in Tab. D are prepared in the factory to be
connected in accordance with the electrical diagram shown in
Fig. 5.
Code
Model
3970229
MB 407/1 - RSM 20
3970230
MB 410/1 - RSM 20
3970231
MB 412/1 - RSM 20
3970232
MB 415/1 - RSM 30
3970233
MB 420/1 - RSM 30
The gas train shown in Tab. E is prepared in the factory to be con-
nected in accordance with the electrical diagram shown in Fig. 6.
Code
Model
3970234
MB 420/1 CT RSM 30
4.6.2
Connections for burners with terminal board
The gas trains shown in Tab. F are prepared in the factory to be
connected in accordance with the electrical diagram shown in
Fig. 7.
Code
Model
3970144
MB 412/1 - RT 20
3970256
MB 412/1 - RT 52
3970180
MB 415/1 - RT 30
3970250
MB 415/1 - RT 52
3970181
MB 420/1 - RT 30
3970257
MB 420/1 - RT 52
Key
PG
Min. gas pressure switch
V
Valve group V1 - V2
VPS Valve leak detection control device
X6
6 pole socket
BN
Brown
BU
Blue
BK
Black
YE
Yellow
20049141
Installation
2
Tab. D
20049868
Tab. E
VPS
L1
N
B5
T6
T7
T8
Tab. F
20049993
2
20049866
8
GB
V
PG
3 1
1
2 3
X 6
3 2 1 N
Ph
V
PG
2
3
1
1
BU
BK
BN
X 6
3 2 1 N
Ph
V
PG
3 1
1
2 3
V 1
V 2
Fig. 5
V1
V2
2 3
Fig. 6
V 1
V 2
Fig. 7