3.5

ELECTRICAL WIRING

WARNING:
Do not swap neutral and phase over, follow the diagram shown carefully and carry out a good earth connection.
The cross section of the conductors must be at least 1 mm
legislation).
The electrical wiring carried out by the installer must comply with the rules in force in the country.
E
SO
CN1
N +
RPM
S2
L2
N
S1
R
PE
TB
B4S3 T2 T1 N
X 7
TL
SB
h1
D7590
~ 50/60Hz 220/230V
3350
TB
G
N
N
A
M
C
B
L1
TS
T6A
N PE L
2
. (Unless requested otherwise by local standards and
TESTING
Check the burner goes off by opening the thermostats.
Check that the burner has locked out during operation
by opening the connector (CN1) inserted in the probe's
red wire, located outside the control box.
X M5
V
1ST
2ST
DO W N
G N D
UP
X M3
N
PE
F
X P4
T6
B5
T8
T7
X 4
TR
KEY TO LAY-OUT
BN – Brown
BK – Black
BU – Blue
RD – Red
WH – White
CN1 – Probe connector
E
– Electrode
H1
– Hour counter
M
– Motor
PS
– Remote reset button
8
GB
PE
M
TB
THE BE DONE
BY INSTALLER
SB – Lock-out indicator
SO – Ionisation probe
TB
– Burner earth
TL
– Limit thermostat
TR
– 2nd stage thermostat
TS
– Safety thermostat
T6A – Fuse
V
– Valve
X4
– 4-pin plug
X7
– 4-pin plug
XP4 – 4-pole socket