Electric Start - Pramac S7200 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

This generator model is provided with both electric start
and recoil start capabilities. Avoid prolonged cranking, as it
can damage the engine.
The required battery is a nominal 12 volt sealed
rechargeable lead-acid battery and can be operated in any
position without leakage. It complies with non-spillable battery
regulations. Its convenient size offers a 30% reduction over
conventional batteries.
Length = 7.14 inches, Width = 3.03 inches,
Height = 6.59 inches, Weight = 12.56 lbs
18AH Rating
UL Recognized
Pramac part number: 0063574
Battery Kit Parts List
Item
Description
A
*Bolt, M5 x M12
B.
*Nut 5MM
C.
*Washer Flat M5
* These are standard parts available at your local hardware
store.
Note: The Positive and Negative Terminals must be con-
nected to the Battery before the Electric Start Feature will
work.
Initial Battery Connection - Refer to the Installation Instructions
Below.
Battery Removal & Installation:
Removal: Remove the nut and bolt from the negative and
positive post, being careful not to short across the terminals.
(Shorting the terminals together can cause sparks, damage to
the battery or generator or even burns or explosions.)
Always abide by the safety warnings provided with the
battery. Remove the battery and re-cycle and dispose of
properly.
Do not short-circuit the battery terminals.
Do not charge in a sealed container.
Keep sparks, flame away.
English

ELECTRIC START

Installation:
Hook up the new battery, or re-install the new battery, as
follows: Place the battery in the position provided. Connect
the Red 10 Gauge wire to the positive (+) terminal and the
Black 10 Gauge wire to the negative (-) terminal with the bolt,
nut, and washer provided. Make sure all connections are tight.
Your battery is now connected and ready for use.
STARTING THE GENERATOR SET
Note: Be sure Oil has been added to the engine as
specified in the Owner's Manual.
Move engine On/Off switch to On position. Push and hold the
On/Off switch in the Start position until the engine starts and
Qty
release.
2
2
Note: If the engine does not start after 5 seconds, stop and
2
wait 10 seconds and repeat this step.
3

Publicidad

Tabla de contenido
loading

Tabla de contenido