MAINTENANCE AND TROUBLESHOOTING
1
MAINTENANCE
Before
carrying
operation, disconnect the device from the
power supply.
Frequently check the installation in order to
detect any sign of deterioration. Do not use the
device if any repair or adjustment is necessary.
A record of all repairs and maintenance operations
must be kept. The owner of the facility must keep
these records safe.
2
PROGRAMMING LOCK KEY AND OPERATIONS COUNTER
1 Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
D1
D2
Parameter
ç
0
Programming lock key
Be sure to remember any
key used, for future access
to the programming
ç
1
Total operations completed
ç
2
P a r t i a l
completed
3
COMMUNICATIONS MODULE
These functions are only available if the optional
communications module has been installed.
1 Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
2 Press the buttons ^ and
t flashing. Press ENTER to confirm. D2 flashes.
D1
D2
Parameter
t
0
FTP communication
1
GSM signal strength
88
Installation Guide
out
any
maintenance
D3
D4
0
0,1
X
X
o p e r a t i o n s
X
X
until D1 shows the letter
V
D3
D4
o
ç
X
X
Every six months
1 Check that the operation and safety devices
(photocells or safety strips), as well as their
installation, have not suffered any damage from the
weather or external agents.
2 Check the operation of the flashing light.
3 Check the device for normal operation.
2 Press the buttons ^ and
ç.
D3 and D4 show the number of operations
completed (see the table).
3 Press ESC to return.
Options or values
The preset option is 0000 (no key). If any figure is
changed, this is considered a key.
Select the required key (starting with D1) using UP and
DOWN. Press ESC to cancel or ENTER to confirm and move
to D2, and so on.
Indicates the cycles completed, multiplying the indicated
figure by an amount, for example:
68
indicates 6,800 cycles completed
6.8
indicates 68,000 cycles completed
Indicates the hundreds of cycles completed. This can be
reset by pressing ST1, ST2 and ENTER at the same time.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm.
t0oç: allows communication with the server.
t1XX: indicates GSM signal strength.
4 Press ESC to return.
Options or values
Immediate communication with the server
Indicates signal strength
until D1 shows the letter
V
until the required D2
V