INSTALLATION
Mechanical safety strip connection (LB or LM)
P13 P14 P15 P16
ENCODER1
P1 P2 P3
P4 P5 P6
Resistive safety strip connection (LR)
P13 P14 P15 P16
P1 P2 P3
P4 P5 P6
76
Installation Guide
EDGE
P24 P25
P24 P25
P17 P18 P19 P20
P21 P22 P23
-FT
AUX
(Test)
24 Vdc
ENCODER2
P7 P8
P9 P10
P11 P12
EDGE
P24 P25
P24 P25
P17 P18 P19 P20
P21 P22 P23
-FT
AUX
(Test)
24 Vdc
ENCODER1
ENCODER2
P7 P8
P9 P10
P11 P12
LR
We recommend installing interior and exterior
strips. If only one is installed, install the exterior
one.
O
If neither a mechanical strip nor a resistive strip is
installed, make an electrical bridge between cable
connectors P24 and P25 of the control board and
programme C901.
O
It is not possible to install mechanical and resistive
strips at the same time.
The mechanical strips are connected serially.
G7 G8
G9 G
1 Connect the contacts of the strip in cable connectors
P24 and P25 of the control board.
2 Duly programme the control board:
Mechanical strip without testing: C901
For further details on programming, see "Starting up
and programming" on page 77.
P239E
We recommend installing interior and exterior
strips. If only one is installed, install the
exterior one.
O
If neither a mechanical strip nor a resistive strip is
installed, make an electrical bridge between cable
connectors P24 and P25 of the control board and
programme C901.
O
It is not possible to install mechanical and resistive
strips at the same time.
The resistive strips are connected in cascade.
G7 G8
G9
1 Connect the end of the strip in cable connectors P24
and P25 of the control board.
2 Ensure the resistance (R) of 8.2kk is installed inside
the strip on the other end.
P239F
3 Check the installation: disconnect the control board
connector and connect an ohmmeter in the
connector: the value must be 8,200k ± 500k.
Operate the strip: the value must now be <1,000k.
4 Duly programme the control board:
Resistive strip: C902
For further details on programming, see
"Starting up and programming" on page 77.