A CLEAN BURN POT GUARANTEES CORRECT OPERATION!
MAINTAINING THE BURN POT AND ITS HOLES ALWAYS WELL CLEAN FROM ANY
COMBUSTION RESIDUES, EXCELLENT COMBUSTION BY THE GENERATOR IS
GUARANTEED OVER TIME, PREVENTING ANY MALFUNCTIONING THAT COULD
REQUIRE TECHNICIAN INTERVENTIONS.
THE "EASY SETUP" FUNCTION IN THE USER MENU CAN BE USED TO ADAPT
COMBUSTION ON THE BASIS OF THE NEEDS DESCRIBED.
IF THE POWER SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY
QUALIFIED PERSON, SO AS TO AVOID ALL RISKS.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE:
ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS
Routine maintenance must be performed at least once a year.
Using pellets as solid fuel, the generator requires annual routine maintenance, which must be performed by a Quali ed technician, using
original spare parts exclusively.
Failure to comply can jeopardise safety of the appliance and make the warranty null and void.
Respecting the frequencies of cleaning reserved for the user described in the use and maintenance manual, the generator is guaranteed
correct combustion over time, preventing any anomalies and/or malfunctioning that could require more interventions of the technician.
Requests for routine maintenance are not contemplated in the product warranty.
DOOR, ASH DRAWER AND BURN POT GASKETS
The gaskets guarantee the tightness of the stove and its consequent good functioning.
They must be controlled periodically. They must be replaced immediately if they are worn or damaged.
These operations must be carried out by a quali ed technician.
CONNECTION TO THE FLUE
Suck and clean the pipe that leads to the ue yearly or any time that it is necessary. If there are horizontal tracts the residues must be removed
before they can obstruct fumes passage.
DECOMMISSIONING END OF SEASON
At the end of each season, before turning the stove o , it is advisable to empty the pellet hopper out completely, removing any residues of
pellets and dust with a vacuum cleaner.
WE ADVISE YOU NOT TO DISCONNECT THE GENERATOR FROM THE ELECTRICAL POWER SUPPLY, SO AS TO ALLOW THE PUMP TO PERFORM THE
NORMAL ANTI-LOCKING CYCLES.
We also recommend disconnecting the generator from the mains and, for added safety especially when children are present, remove the
power cable. Routine maintenance must be performed at least once a year.
72
WWW.LANORDICA-EXTRAFLAME.COM
ENGLISH
BURN POT HOLES