10 DISASSEMBLING THE DISPENSER
10. 1 OPENING THE DISPENSER
1 Remove the rear panel, prising it open with a screwdriver inserted in the purpose-designed slot, then remove the condenser
filter.
2 Loosen the fastening screws and remove the side panels.
The side panels cannot be removed if the rear panel has not previously been
disassembled.
3 Loosen the screws and remove the front panel. Then remove the condensation water drain cover.
4 Once you have removed the cover, the tank and mixer, loosen the fastening screws on the condensation water collection tray
IMPORTANT