THIS BUBBLER HAS AN AUTOMATIC DRAIN VALVE. AFTER EACH CLEANING, THE EXCESS
WATER WILL BE AUTOMATICALLY EVACUATED.
A MESSAGE WILL APPEAR ON THE TOUCH SCREEN IN CASE THE WATER EXCEEDS THE
INDICATED LEVEL.
IT IS NECESSARY TO EMPTY COMPLETELY AND FILL THE BUBBLER AGAIN WHEN THE
THERMOSTAT REACHES 40º - 45º. THE DECARBONIZED SESSION CAN BE FINISHED BUT
PROCEED WITH THE EMPTYING BEFORE THE NEXT.
THERE IS A DRAIN TAP WHICH IS LOCATED ON THE SIDE OF THE MACHINE.
Fill exclusively with tap water.
During the refilling process, check the sight glass, in the unlikely event that water
appears in the sight glass and the touch screen has not warned that the level has been
reached, it will be necessary to pour into the bubbler the equivalent of a tablespoon of
water from the tank main that we can remove through the tap that is at the back of the
machine.
DEPOSIT TAP
EXTERNAL FILTER LEVELS
ATTENTION - FILL WITH DISTILLED OR OSMOSIS WATER UP TO
THE BLUE LINE
Over time this bubbler will also fill with water, resulting from the
recovery of gas condensation. After each cleaning, the filter
must be emptied to the blue line (MINIMUM) if necessary.
The excess water must be kept in a clean container of exclusive
use to reuse it when it is necessary to fill the main tank of the
machine.
Although it comes out brown, it does not matter if it is used
equally.
BUBBLE LEVEL
WATER CONTROL SIGHT