Description Of Rotary Switch Functions; Dc Voltage Measurement - HT 60 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.3.

DESCRIPTION OF ROTARY SWITCH FUNCTIONS

4.3.1. DC Voltage measurement

The maximum input DC voltage is 600V. Do not measure voltages
exceeding the limits given in this manual. Exceeding voltage limits could
result in electrical shocks to the user and damage to the instrument.
Fig. 2: Use of the instrument for DC voltage measurement
1. Select position V
2. Insert the red cable into input terminal VHz%CAPTemp 
into input terminal COM
3. Position the red lead and the black lead respectively in the spots with positive and
negative potential of the circuit to be measured (see Fig. 2). The display shows the
value of voltage.
4. The message
measurable value.
5. When symbol
"
opposite direction with respect to the connection in Fig. 2.
6. To use the HOLD function and Relative measurement, see § 4.2
. The symbol
DC
"
O.L.
indicates that the value of DC voltage exceeds the maximum
"
"
-
appears on the instrument
"
CAUTION
is shown on the display.
"
s display, it means that voltage has the
'
EN - 8
HT60
and the black cable

Publicidad