Temperature Coefficient: 0.1 x (specified accuracy) / °C (<
18°C or > 28°C).
Auto Power Off
changes.
Altitude: 2000m.
Power: Standard 9-volt battery.
Battery Life: 75 hours typical with carbon-zinc battery.
Jaw Opening Capability: 57mm conductor, 70 x 18mm bus
bar.
Size (H x W x D): 281 x 108 x 53 mm.
Weight: Approx. 570g grams (including battery).
Accuracy is given as ±([% of reading]+[number of least significant
digits]) at 18°C to 28°C, with relative humidity up to 70%.
DC Voltage
Range
0,000...6,599V
6,60...65,99V
66,0...659,9V
660...1000V
Overload protection: 1000V DC or 750V AC rms.
AC Voltage (True RMS)
Range
0,000...6,599V
6,60...65,99V
66,0...659,9V
660...750V
Crest Factor: ≤3.
AC coupled true rms specified from 5% to 100% of range.
:
30 minutes after rotary switch or mode
Resolution
0,1mV
1mV
10mV
1V
Resolution
0,001V
0,01V
0,1V
1V
CMP-2000 – USER MANUAL
Accuracy
±(0,5% rdg + 2d)
Accuracy
±(1,5% rdg + 8d)
50...500Hz
Input
impedance
>100MΩ
10MΩ
9,1MΩ
9,1MΩ
Input
impedance
>100MΩ
10MΩ
9,1MΩ
9,1MΩ