Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
Display Parameter
Closing the bottom gap
when the garage door
is closed
Opening force
Closing force
Photocell
Automatic garage door
closing
ADJUSTING THE TRANSMITTER
Adjusting (learning):
In the standby mode press and hold the "-" button until the display shows ".":
Then press repeatedly the button on the remote control, the dot will
blink rapidly and will turn off after about 2 seconds. Learning is completed
successfully. When learning goes wrong, the dot will not blink and will turn
off after about 2 seconds.
In stand-by mode, press and hold the "-" button for about 6 seconds, the dot on the
display will turn on and off, then release the "-" button. All remote controls have been
removed. After this operation, all remote controls must be re-adjusted ("taught").

ADVANCED SETTINGS

To access the advanced settings, press and hold the "P" button until the display shows
"F". Repeatedly pressing the "P" button will move between successive parameter
settings. Use the "+" and "-" buttons to set the required value, use the "P" button to
confirm and move to the next parameter setting:
88
Settings
Range: 0-9 every 5 mm.
Range: 0 to 9 – the higher the value the
higher the opening force.
Range: 0 to 9 – the higher the value the
higher the closing force.
Range:
0 – photocell missing
1 – works only during garage door closing.
2. works only during garage door closing and
opening
Range:
0 – automatic garage door closing disabled
1-9 – delay of automatic garage door closing
disabled set between 1 and 9 minutes
Rev. 20.11.2017
Display
Parameter
Setting remote controller
push buttons
Setting automatic closing
of garage door
Restoring factory settings
Rev. 20.11.2017
Setting
Range:
0 – opening and closing is done by using
two buttons on the remote control.
1 – opening and closing is done by using
one button on the remote control, the
other button remains inactive.
2 – opening and closing is done by using
one button on the remote control, the
other button is used to switch on and off
the light in the drive.
Range:
0 – automatic closing is independent from
the photocell
1 – automatic closing is disabled when the
photocell is set to "0"; automatic closing
is enabled when the photocell is set to
"1" or "2".
Range:
0 – no factory settings restored.
1 – factory settings restored with the use
of remote controls.
2 – factory settings restored with remote
controls removed (disabled).
89

Publicidad

Tabla de contenido
loading