emmeti XECO-XX15W Serie Manual Instalación E Instrucciones Para El Uso De La Unidad Interna página 53

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
5. UNIT POSITION
1. DESCRIZIONE DEI COMPONENTI
Air conditioner has to be placed in a well-ventilated and easy to reach place.
Air conditioner has not to be placed in the following places:
a) Places where there are machines oils or other oils fumes.
b) Along the coast with high salt concentration in the air
c) Near resurgences with high content of sulphuric gases
d) In areas with high tension fluctuation, e.g. factories etc.
e) In vehicles or boats
5.1 Indoor unit positioning
Avoid sources of heat or steam
underneath or near the unit.
Determine the position that is favourable for the
connections with the external unit and the con-
densation water draining.
5.2 External unit positioning
If possible, avoid exposing the unit to direct
sunlight, particularly in early afternoon.
On the contrary, provide for a suitable protection
that does not obstruct the free circulation of air.
In the models pay particular attention to snowfall,
including snow falling from roof pitches which
could obstruct air circulation.
Install the unit on a solid wall that is
not subject to vibrations.
Determine a position that is favourable for noise-
less working of the machine. For example, avoid
corners that act as cash reverb.
Avoid positioning in correspondence with areas
that can worsen the negative effects of atmo-
spheric agents such as eaves drains or downpipe
drains.
Select a position in which noise and the air jet do
not damage or bother people, animals or plants.
f) In kitchens with a lot of oil fumes and with high humidity percentage
g) Near machines issuing electromagnetic waves
h) Places with acid or alkaline fumes
TV, radio, acoustic equipment have to remain at a minimum distance of
1 m from the internal unit, the external unit, the power supply cables,
pipes; otherwise images could result not clear and some noise could be
detected.
Avoid having nearby obstacles to the
air circulation of the unit.
Make sure to observe the "minimum operational
distances".
Select the position that is favourable for air
circulation and facilitates the drain of the con-
densation water.
Make sure the "minimum operational distances"
are observed.
GB
GB
Determine the position that is favou-
rable for the circulation as well as
the even distribution of the thermal
flow produced by the unit.
Max 2,5 m
Min 2 m
53

Publicidad

Tabla de contenido
loading

Tabla de contenido