6. INSTALLATION OF THE INTERNAL UNIT
Installation and maintenance activities on the air conditioners can
be done by personnel and companies holding appropriate certifi-
cate according to the Regulation (EC) Nr. 303/2008 which provides
the minimum requirements of the companies and of the personnel
about fixed units of refrigeration, air condition and heating pumps
which contain some fluorinated greenhouse gases, according to
the Regulation (EC) nr. 842/2006 of the European Parliament and
of the Council.
- Installation must be performed by qualified and authorized personnel.
- Do not attempt to install the unit by yourself.
- For any repairs, contact the service centre.
- Repairs of an electrical nature must be performed by qualified
electricians.
- Improper operations may cause serious harm to the user.
- You can find a list of service centres at the website www.emmeti.com
The right installation of the air conditioner assure its efficiency
Therefore we invite you to follow the instructions carefully about positio-
ning, installation, connexions and test listed in these manuals.
CAUTION
Danger cut: use of gloves.
If the conditions are met Arrange for work at height.
6.1 Installation template fixing and positioning
of the hole on the wall
- Ensure the appropriate structure of the surface and choose the right
kind of expansion plug
- Determine the position of the internal unit installation; refrigerant lines
can be oriented in different directions as shown in Fig. A
- Install the fixing bracket with 6 screws (Fig. B) verifying the right hori-
zontality of the same.
Left rear
Left side
Lower
Fig. A
Ring
Screw
Fig. B
56
- Hole to the wall has to be done in the position showed into paragraph nr.
Fig. C
6.2 Connexion of the internal unit to the
- Lift the frontal louver, remove the terminal strip cover by acting on the
Fig. D
- Insert the cable from the back side of the unit and then take it off on the
Right rear
Right side
Lower
Fig. E
- Loosen the screws and insert the cable ends completely in the terminal
Fig. E
5.6, according to model and to pipes orientation."
terminal strip
screw, as shown in Fig, D
frontal side, as shown in Fig E
block, after this tighten the screws.
GB
GB
5÷15°
70 mm
10 mm
10 mm
50 mm
Un