Turbo Function - emmeti XECO-XX15W Serie Manual Instalación E Instrucciones Para El Uso De La Unidad Interna

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
8. AIR CONDITIONER USE
1. DESCRIZIONE DEI COMPONENTI
8.10 Regulation of the air flow direction
8.10.1 Vertical adjustment
The SWING function can be used with all the air conditioner's operating
modes and determines the vertical motion of the air deflector thus
obtaining an even distribution of the air in the room.
When the air conditioner is first turned on, the deflector goes
automatically to position D if the heating function or the automatic
heating mode is enabled. In all other modes, the deflector will go to
position L1. When the indoor unit is operating and the SWING function is
enabled, the deflector can move to 7 different positions. In heating mode
in positions L , A , B , C , D , continuous movement from L to D, stopped in
any position between L and D. In all other operating modes in positions
L1 , A1 , B1 , C1 , D1 , continuous movement from L1 to D1, stopped in any
position between L1 and D1. The deflector is closed in position 0.
Attention!
The position of the deflector must be set with the remote control with
the SWING command and never manually, or the deflector could be
damaged.
During operation in cooling mode, if the deflector remains positioned
facing downwards for a long time, drops of condensation may appear.
8.11.2 Horizontal adjustment
The horizontal orientation of the air flow is fixed and must be carried out
manually as in Figure C

8.11 TURBO function

Press this button to activate or deactivate the turbo fan speed. This
speed is available in the Cooling and Heating
operating modes. After setting the turbo fan speed, the corresponding
icon will appear on the remote control display
The turbo fan speed can also be deactivated by changing the operating
mode or changing the fan speed by pressing the FAN button. The TURBO
function is used to reach the set temperature as quickly as possible, both
when cooling as well as when heating.
8.12 BLOW function
The X-FAN programme is used to remove any condensation from the
indoor unit exchanger by pressing the OFF key in the Cooling and
Dehumidification operating modes. An
te control display when this programme is activated. When shutting
down, the unit will go into stand-by and the fan will continue to operate
at the minimum speed with the horizontal outlet fins in an open position
for an additional 10 minutes. To stop the X-FAN programme, press the
X-FAN key again: the fan will turn off and the fins will close.
.
icon will appear on the remo-
0 (0°)
L
A
B
C
D
Fig. A
Function
Fig. C
GB
GB
0 (0°)
L1
A1
B1
C1
D1
Fig. B
Function
69

Publicidad

Tabla de contenido
loading

Tabla de contenido