6. INSTALLATION OF THE INTERNAL UNIT
ioni
stra
basso
Note
To use the lateral exits you must remove the pre-cuts with a tool
con nastro adesivo
Cavo elettrico interno/esterno
Pre-cut
Fig. M
cnicamente isolante
6.4 Condensation drain pipe
bo flessibile
You have to connect a drain pipe to the hose end of the drain pan of the
scarico
internal unit to carry the drain into the requested place, both outside
and inside the house.
- Insert a drain pipe of condensation to the hose end (Ø16 mm)
- Use a plastic pipe rigid enough to avoid squashing on the curvatures.
- Fix the pipe to the drain and block it with a clamp-band
- Insulate with an insulated sheath of 9mm thickness the whole pipe
inside the house to avoid drip as a consequence of an external con-
densation of the pipe.
- Verify the absence of siphons or counterslopes next to the internal
unit drain.
Attention
Before pipes connection of the refrigerant circuit you should verify the
right operation of the drain. Pour some water into the drain pan placed
under the fins battery of the internal unit and verify its right outflow.
Attention
Place the condensation water drain in order not to create damages to
people or things.
It is advisable to maintain a visual check of the drain at the end of the
pipe or to add a transparent piece into the same pipe when it goes into
a not inspectable drain.
Do not install the drain as shown below
The end is
It becomes
immersed in
high midway.
water
58
Tappo pre-inciso
per tubazioni in
uscita sinistra
Tubazione
Piastra di
supporto della
tubazione
5 cm
It waves.
The gap with
the ground is
too small.
6.5 Internal unit positioning on the installation
template
Please make sure that pipes and cables go trough the hole on the wall
6.5.1 Internal unit fixing.
Fix securely the internal unit on the top notches of the installation template.
Move the unit from one side to another to verify that all has been fixed
safely (Fig. N)
Fig. N
In order to fix the body onto the mounting template, hold up the body
aslant from the underside and then put it down perpendicularly (Fig. O).
Fig. O
6.5.2 Internal unit removing
When the unit has to be moved, please use your own hand to lift it and leave
the handle, then lift the lower part of the unit slightly outward and lift the unit
until it leaves the assembling plate.
Fig. P and Fig. Q
There is the
bad smell
from a ditch
Push
Fig. P
Fixing template
Mounting plate
piastra di montaggio
Push
GB
GB
Signs
Fig. Q