Connecting Electric Power Tools; Temperature Monitoring; Connect With The T-Loc; Use/Adjust Carrying Strap - Festool CTL SYS Manual De Instrucciones

Ocultar thumbs Ver también para CTL SYS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
6.2

Connecting electric power tools

WARNING
Risk of injury
Observe the maximum appliance socket con-
nected load (see chapter "Technical data")
Switch off the electric power tool.
Connect the electric power tool to the appliance
socket [1-10].
6.3
Connecting the suction hose
at the extraction opening [3a]
Connect the suction hose to the elbow at the ex-
traction opening.
at the exhaust opening [3b]
Open flap at rear of dust extractor.
Connect suction hose to elbow at exhaust opening.
7
Settings
7.1

Temperature monitoring

Before reaching a critical temperature, the tempera-
ture monitor switches off the dust extractor.
Switch off the dust extractor, allow to cool for
about 5 minutes, then switch on again.
 Not possible to switch on: Contact Festool cus-
tomer service workshop.
7.2

Connect with the T-Loc

The dust extractor can be closed, opened and con-
nected by turning the T-Loc:
– Close dust extractor [4a].
– Open dust extractor [4b].
– Connect dust extractor to storage box [4c].
Before lifting, always close the T-Loc at the
dust extractor or connect to the storage box
and check for secure holding.
Max. load for connection to other Systainers: 20 kg
7.3

Use/Adjust carrying strap

Max. permissible load of carrying strap: 20 kg
The carrying strap can be attached in two different
positions:
– Carrying the dust extractor: Carrying strap at dust
extractor [5a]
– Carrying storage box with dust extractor: Carrying
strap at storage box [5b]
Before lifting, check the carrying strap for
proper functionality and put T-loc at dust ex-
tractor into corresponding position.
Adjust the length of the carrying strap at the adjust-
ing tab [5c].
8
Working
CAUTION
Hazardous dust
Damage to the respiratory passage
Always use a filter bag!
 Two cleaning nozzles are stored in the inside of
the dust extractor [6-1].
Observe the following instructions:
– The dust extractor is a stationary system and not
suitable for pulling at the cable and hose. Use han-
dle [1-4].
– Static charge may occur if an anti-static suction
hose is not used. The user may suffer an electric
shock.
When extracting dust that exceeds the permit-
ted limit values, only extract from a single ma-
chine (electric or air tool).
Observe the following when extracting dust generat-
ed by operating electric power tools:
Ensure there is adequate ventilation! Observe re-
gional regulations!
Limit values: Exhaust air max. 50% of the clear air
volume
Formula: Room volume V
Please note the following after the work:
Switch off the dust extractor and pull out the
mains plug.
Wind up the mains power cable.
Empty the dirt trap.
Place suction hose [1-3] and mains power cable
in storage box.
Clean inside and outside of dust extractor by ap-
plying vacuum and wipe.
Place the dust extractor in a dry room inaccessi-
ble to unauthorised users.
9

Service and maintenance

WARNING
Risk of injury, electric shock
Always disconnect the mains plug from the
socket before performing maintenance work on
the machine!
All maintenance and repair work which requires
the motor housing to be opened must only be
carried out by an authorised service workshop.
CTL SYS
x air renewal rate L
R
W
GB
13

Publicidad

Tabla de contenido
loading

Tabla de contenido