Problem
The power LED (4 or 11)
does not light up when
connecting the unit to
the mains.
Batteries cannot be
charged.
6. MAINTENANCE
Clean the equipment with a dry and soft cloth. Never use cleaning agents
or solvents.
7. TECHNICAL SPECIFICATION
- Frequency: 1,8 GHz
- Range: Up to 300 m under optimum conditions. It is possible to reach up to
50 m in buildings (as a result of walls, doors etc.)
- Baby unit (emitter):
· Adaptor: Input: 100~240 V AC, 50/60 Hz, 150 mA. Output: 7 V DC, 420 mA,
Centre = +
- Parent unit (receiver):
· Batteries: 2 x AAA 1.2V 450mAh Ni-MH (included)
· Adaptor: Input: 100~240 V AC, 50/60 Hz, 150 mA. (hard wired) Output:
7 V DC, 420 mA
- Transmitting power:
· Average: 10 mW
· Maximum: 250 mW
Possible Cause – things to do/check
· Check whether there is a power failure. Check
whether all connections are ok and both units
are switched on (on/off key, 1 or 9).
· AC/DC adaptor has not been connected: plug
the mains adaptor into a mains power socket.
· Non-rechargeable batteries have been used,
only special batteries can be recharged
(2 x AAA 1.2V 450mAh Ni-MH): please check
the batteries type and change them for the
provided ones.