3 INSTALLATION

The servodrive must be installed according to the instructions of the SCA06 User's
Manual.
If pollution degree 2 cannot be guaranteed, IP54 protection class must be used.
The connections of the Safety signals are made at connector X7, located at the bottom
of the servodrive, according to
Additionally, the type of safety signals coming from the installation must be chosen at
a Dip Switch. See location at
before energization, according to the description below:
"D" for Dry Contact devices, i.e., all devices that have electromechanical output
contacts, like relays.
"O" for OSSD (Output Signal Switching Device), i.e., devices that have outputs
containing test pulses.
NOTE!
The 24 Vdc power supply must attend Low Voltage Directive (2006/95/
EC), applying the specifications of IEC 61131-2:2007, Programmable
controllers - Part 2: Equipment requirements and tests and must attend
one of the following specifications:
Safety extra-low voltage (SELV) type, according to EN60950.
Protected extra-low voltage (PELV) type, according to EN60204.
The minimum installation necessary to operate the safety function is shown at
3.3 on page
15.
Figure 3.1 on page 13
Figure 3.1 on page
Figure 3.1: X7 connector and OSSD selector
and
Figure 3.2 on page
13. The Dip Switch must be set
Installation
14.
Figure
SCA06 | 13