2) Press the button SET repeatedly until the dis-
play shows
and the current identification
number ( ...
or
3) In the setting range
the button – (5) to search in descending order or
press the button + (6) to search in ascending
order. Use the corresponding button to set the
transmitter to the identification number of the
receiver unit (the transmitter will only respond to
the REMOSET signal of this receiver unit) or
select
(the transmitter will respond to the
REMOSET signal of any receiver unit).
4) Press the button SET to confirm. The display
briefly shows
normal mode.

5.1.6 Lock function

When the lock function has been activated, you will
no longer be able to switch off the transmitter. From
the setting modes, you will only be able to activate
the mode for the lock function in order to deactivate
the lock. When the transmitter is locked and you set
the on / off switch (2) to OFF or press a button, the
display will show
Note: Do not leave the on / off switch in the position OFF
when the transmitter is locked; the display backlight will not
be extinguished automatically and there will be unneces-
sary power consumption.
Activating the lock
1) Keep the button SET (4) pressed until the dis-
play briefly shows
ting mode (group indication starts flashing).
2) Press the button SET repeatedly until the dis-
play shows
3) To activate the lock, press the button + (6). The
display shows
4) Press the button SET to confirm. The display
briefly shows
normal mode.
Deactivating the lock
1) Make sure that the on / off switch (2) is set to ON.
2) Keep the button SET (4) pressed until
flashing in the indication
3) To deactivate the lock, press the button – (5).
The display shows
4) Press the button SET to confirm. The display
briefly shows
normal mode.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
).
,
...
. The unit will return to the
(lock on).
and then the group set-
(lock off).
.
. The unit will return to the
.
.
. The unit will return to the
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
6 Specifications
Carrier frequency range: . . 740 – 776 MHz
, press
Frequency stability: . . . . . . ±0.005 %
Transmission power: . . . . . switchable
Audio frequency range: . . . 40 – 18 000 Hz
Ambient temperature: . . . . 0 – 40 °C
Power supply: . . . . . . . . . . 2 × 1.5 V battery of
Operating time: . . . . . . . . . > 25 h (for alkaline
Dimensions: . . . . . . . . . . . 68 × 172 × 21 mm
Weight: . . . . . . . . . . . . . . . 77 g (w/o batteries)
Microphone connection: . . mini XLR, 4 poles
1 = ground
2 = 5 V operating voltage for the microphone
3 = signal input
4 = impedance correction
Lavalier microphone CM-501 supplied
Type/directivity: . . . . . . . . . electret microphone /
Frequency range: . . . . . . . 100 – 15 000 Hz
Sensitivity, impedance: . . . 3.2 mV/Pa at 1 kHz,
SPL max.: . . . . . . . . . . . . . 130 dB
Power supply: . . . . . . . . . . via pocket transmitter
Weight: . . . . . . . . . . . . . . . 20 g
Subject to technical modification.
starts
table on page 21
10 mW/50 mW
size AA (not supplied)
batteries 3400 mAh)
cardioid
2.2 kΩ