To be integrated with a complete reading of the technical speci cations
Positioning and installing
•
First ignition performed by authorised CAT who released the guarantee certi cate
•
Aerazione nel locale
•
Il canale da fumo/la canna fumaria riceve solo lo scarico della stufa
• Room ventilation
• Only the stove outlet passes through the smoke channel/chimney ue
• The smoke channel has: a maximum of 2 curves, a maximum 2 horizontal metres
• Chimney pot that is high enough to avoid downdraft areas
• The discharge pipes are made of a suitable material (stainless steel is recommended)
• When using any ammable materials (e.g. wood), all precautions have been taken to prevent a re hazard
Use
• Good quality, dry pellets are used
• The chimney pot and ash compartment are clean and well positioned
• The door is closed properly
• The combustion chamber is inserted properly into the relevant compartment
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
TELEPHONE COMBINER FOR REMOTE IGNITION (code 281900)
The stove can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the stove via the
optional cable (code 640560).
KIT 11 for channelling hot air into an adjacent room, with max channelling pipe length 1.5 m (code 645700).
KIT 11 BIS for channelling hot air into a non-adjacent room, with max channelling pipe length 5 m (code 645710).
CHECK LIST
OPTIONAL
CLEANING ACCESSORIES
GlassKamin
(code 155240)
Used for cleaning the
ceramic glass
- 47
-
Ash vacuum cleaner
without motor
(code 275400)
User for cleaning
the hearth