THERMO TECHNICAL CHARACTERISTICS according to EN 14785
Heat output
Yield / Ef ciency
Emissions CO 13% O
2
Maximum ue gas temperature
Minimum draught
Mass ow rate of ue gas
Fuel consumption
Hopper capacity
Autonomy
Volume riscaldabile *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging FANTASY / FATA / SIRENA / STORY
* The heatable room dimensions are calculated on the basis home insulation in compliance with Italian law 10/91, and subsequent
changes together with an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL CHARACTERISTICS

Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power supply* (see page 38)
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) caution: live parts. Servicing and/or inspections must be carried out by quali ed staff.
The data shown above is purely indicative.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.

SAFETY DEVICES

• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on de ned parameters.
• VACUUM GAUGE:
positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• AIR FLOW SENSOR:
located in the suction channel, it is activated when the combustion air ow is not correct, with consequent pressure problems in
the smoke circuit causing the stove to shut-down.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
CHARACTERISTICS
100
400
- 29
-
Nominal power
Reduced power
13,2
92,5
0,019
96
12 - 5
13,5
3
23,5
7
345
80
40
271 / 248 / 248 /230
230Vac +/- 10% 50 Hz
si
Infrared
2AT, 250 Vac, 5x20 Fuse
2AT, 250 Vac, 5x20 Fuse
5,1
kW
93,3
%
0,038
%
70
°C
10 - 3
Pa
7,4
g/s
1,1
kg/h
kg
19
hours
3
m
mm
mm
kg
W
W