Operating Elements And Connections; Front Panel; Rear Panel; Safety Notes - IMG STAGELINE PMX-160 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
All operating elements and connections de-
GB
scribed can be found on the fold-out page 3.
1 Operating Elements
and Connections

1.1 Front panel

1 Input MIC (XLR jack, balanced) to connect a
microphone,
for each channel 1 – 6
2 Control EFFECT, for each channel 1 – 6: will
define the level at which the channel signal is
fed to the internal echo effect processor and
thus the effect intensity for the channel
3 Input LINE (unbalanced) to connect a unit
with line signal level, e. g. musical instrument,
for each channel 1 – 6
– channels 1 to 4 for mono units:
1 × 6.3 mm jack
– channels 5 and 6 for stereo units:
2 × 6.3 mm jack
4 TREBLE and BASS controls,
for each channel 1 – 6
5 Volume control GAIN,
for each channel 1 – 6
6 Volume control CD / TAPE for the unit at the
input CD INPUT (18)
7 Graphic 5-band equalizer for sound correc-
tion of the master signal
8 Volume control PHONES for the headphone
output (9)
9 Connection (6.3 mm jack) for headphones for
monitoring the master signal
10 Output TAPE REC (RCA jacks), e. g. to con-
nect a stereo recorder; the adjustments of the
equalizer (7) and the control MASTER (14)
will not affect the output signal
11 LED level indication for the master signal
12 LED POWER ON
13 Button PHANTOM POWER (with indicating
LED) for central activation of the 15 V phan-
tom power supply for all MIC jacks (1)
Please observe the "Caution" notes in chap-
ter 4.1.
14 Volume control MASTER for the overall vol-
ume: will define the level at which the master
signal is fed to the speaker output (22)
15 Control EFFECT to adjust the overall volume
of the internal echo effect
16 Control ECHO to adjust the number of
repeats for the internal echo effect
17 Control DELAY to adjust the delay time for
the internal echo effect
18 Input CD INPUT (RCA jacks) for a stereo
reproducer with line signal level, e. g. CD
player

1.2 Rear panel

19 POWER switch
20 Support for the mains fuse; always replace a
blown fuse by one of the same type
21 Mains jack for connection to a socket (230 V~ /
50 Hz) via the mains cable
6
22 Mono output of the power amplifier (two
6.3 mm jacks, connected in parallel) to con-
nect speakers
IMPORTANT: The total impedance of the
speakers must not fall below 4 Ω.
23 Connections EFFECT LOOP (two 6.3 mm
jacks, unbalanced) for an effect unit
– input RETURN: connection to the output of
the effect unit
– output SEND: connection to the input of
the effect unit

2 Safety Notes

This unit corresponds to all required directives of
the EU and is therefore marked with
WARNING The unit uses dangerous mains
voltage. Leave servicing to skilled
personnel only and never insert
anything into the air vents; inex-
pert handling may result in electric
shock!
Please observe the following items in any case:
G
The unit is suitable for indoor use only. Protect
it against dripping water and splash water,
high air humidity and heat (admissible ambi-
ent temperature range 0 – 40 °C).
G
Do not place any vessel filled with liquid on the
unit, e. g. a drinking glass.
G
The heat generated within the unit must be
dissipated by air circulation; therefore, never
cover the air vents on the housing.
G
Do not operate the unit and immediately dis-
connect the mains plug from the socket
1. if the unit or the mains cable is visibly dam-
aged,
2. if a defect might have occurred after the unit
was dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by
skilled personnel.
G
Never pull the mains cable to disconnect the
mains plug from the socket, always seize the
plug.
G
For cleaning only use a dry, soft cloth; never
use water or chemicals.
G
No guarantee claims for the unit and no liabil-
ity for any resulting personal damage or mate-
rial damage will be accepted if the unit is used
for other purposes than originally intended, if it
is not correctly connected or operated, or if it
is not repaired in an expert way.
G
Important for U. K. Customers!
The wires in this mains lead are coloured in
accordance with the following code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured green and yel-
low must be connected to the terminal in the
plug which is marked with the letter E or by
the earth symbol
, or coloured green or
green and yellow.
2. The wire which is coloured blue must be
connected to the terminal which is marked
with the letter N or coloured black.
3. The wire which is coloured brown must be
connected to the terminal which is marked
with the letter L or coloured red.
Warning – This appliance must be earthed.
If the unit is to be put out of operation
definitively, take it to a local recycling
plant for a disposal which is not harmful
to the environment.
3 Applications
.
The powered mixer PMX-160 in a rugged,
portable housing is specially designed for musi-
cians and applications on stage.
The PMX-160 combines a 6-channel mixer
and a mono power amplifier. An integrated effect
processor will create echo effects, separately
adjustable for each input channel. It will also be
possible to connect an external effect unit for
processing the master signal.
4 Connection
Prior to connecting any units or to changing any
existing connections, switch off the powered
mixer.

4.1 Audio sources

1) Connect microphones to the XLR jacks MIC
(1). The XLR jacks are designed for balanced
signals.
If required, it will be possible to activate a
central 15 V phantom power supply for all
MIC inputs (necessary when using capacitor
microphones operating with this phantom
power supply): Engage the button PHAN-
TOM POWER (13); the LED above the button
will light up to indicate activation.
CAUTION
G
Do not connect any microphones with
unbalanced output when the phantom
power has been activated; otherwise
these microphones may be damaged.
G
To prevent switching noise, only actuate
the button when the powered mixer has
been switched off.
2) Connect audio units with line signal level
to the 6.3 mm jacks LINE (3). These jacks are
designed for unbalanced signals.
– Connect line units with mono output (e. g.
instrument preamplifiers) to the mono
inputs of the channels 1 – 4.
– Connect line units with stereo output (e. g.
keyboard) to the stereo inputs of the chan-
nels 5 and 6.
The RCA jacks CD INPUT (18) allow con-
nection of an additional stereo unit with line
signal level (e. g. a CD player or the replay
output of a recorder).
Note: In each channel 1 – 6 either use the input MIC or
the input LINE; it will not be possible to switch over
between the two inputs.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

20.2550

Tabla de contenido