Calibration Procedure Notes - Balluff BTL7-A -M -A-S32 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL7-A/C/E/G_ _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/S140/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
6
Calibration procedure (continued)
6.5

Calibration procedure notes

Prerequisites
The calibration device is in place or the programming
inputs are connected.
The BTL is connected to the system controller.
Voltage or current values from the BTL can be read
(using a multimeter or the system controller).
Values for zero and end point
Any desired position of the magnet can be used as the
zero or end point. However, the zero and end points
may not be reversed.
The absolute zero and end points must lie within the
minimum or maximum limits of what can be output
(see value table).
The distance between the null point and end point
must be at least 4 mm.
The last set values are always saved, regardless
of whether the setting was ended using the
buttons, the programming inputs or
automatically after 10 min. have expired.
Value table for teach-in and adjustment
The following examples refer to BTL with 0 to
10 V or 4 to 20 mA output.
For all other versions, use the values in the
value table below.
Output
BTL
gradient
Rising
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for teach-in and adjustment
www.balluff.com
Null point
Unit
Min.
Null
value
value
for adjustment
-0.5
V
0
-10.5
-10.0
V
mA
0
0
mA
3.6
4.0
V
+10.5
+10.0
V
+10.5
+10.0
mA
20.4
20.0
mA
20.4
20.0
Identification
Identification
for teach-in
2.0
4.0
2.0
4.0
6.0
12.0
6.0
12.0
8.0
6.0
-2.0
-4.0
14.0
8.0
14.0
8.0
End point
End
Max.
Error
value
value
value
+10.0
+10.5
+10.5
+10.0
+10.5
+10.5
20.0
20.4
20.4
20.0
20.4
3.6
-0.5
-0.5
0
-10.0
-10.5
-10.5
0
0
20.4
4.0
3.6
3.6