Electrical Connections; Remote Condenser Unit; [A] Unpacking, Inspection, Preparation - Hoshizaki IM-240DNE Manual De Instalación

Ocultar thumbs Ver también para IM-240DNE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
ENGLISH

7. ELECTRICAL CONNECTIONS

This icemaker requires an earth that meets the national and local electrical code requirements.
To prevent possible severe electrical shock to individuals or extensive damage to the unit, install a proper earth wire to the icemaker.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 13A supply. The electrical supply must be protected by a suitable circuit
breaker.
* Stacked icemakers should each have a separate receptacle, but they must all be connected in parallel to the same single
phase supply or circuit with sufficient ampacity. In addition and to avoid nuisance tripping, individual circuit breakers for each
machine should not be used.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.
* Usually an electrical permit and services of a licensed electrician are required.
* If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centres.
* In accordance with the requirement of the IEC standard, the maximum permissible system impedance (Zmax) at the interface
point of the power supply to be connected with this icemaker must be 0.23+j0.23 ohm. Determine in consultation with the
supply authority, if necessary, that the icemaker is connected only to a supply of 0.23+j0.23 ohm or less.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to the terminal in the plug which is marked with the letter
E or by the symbol
terminal which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the
terminal which is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for the plug supplied with your product, the plug must be
removed (cut off if it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of. There should be no attempt to
reuse it. Inserting such a plug into a socket elsewhere presents a serious risk of electrical shock.
* The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer's reference number stamped on
the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS 1362.

8. REMOTE CONDENSER UNIT

[a] UNPACKING, INSPECTION, PREPARATION

1) Unpack and remove shipping carton, tape(s) and packing.
2) Remove the top panel.
THIS APPLIANCE MUST BE EARTHED
or coloured Green or Green-and-Yellow. The wire which is coloured Blue must be connected to the
WARNING
6

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido