Descargar Imprimir esta página

Fein Dustex 35 LX AC Manual De Instrucciones página 38

Ocultar thumbs Ver también para Dustex 35 LX AC:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72
OBJ_BUCH-0000000207-002.book Page 38 Thursday, May 9, 2019 9:15 AM
en
38
forming maintenance and repair
work, all contaminated components
that cannot be cleaned to satisfactory
must be disposed of. Such compo-
nents must be disposed of in imper-
meable plastic bags conforming with
the valid regulations for the disposal
of such waste.
For maintenance on behalf of the
user, the vacuum cleaner must be
disassembled, cleaned and main-
tained as far as feasible, without caus-
ing a risk for the maintenance
personnel or other
persons. Prior to disassembly, the
vacuum cleaner should be cleaned in
order to prevent any risks.
The room/enclosure in which the
vacuum cleaner is disassembled
should be well ventilated. Wear per-
sonal protective equipment during
Fault Finding.
Malfunction
Vacuum cleaner can-
not be switched on.
Reduced vacuuming
capacity.
Dust escapes during
vacuuming.
maintenance. After the maintenance,
the maintenance area should be
cleaned.
Products that have come into contact
with asbestos may not be sent in for
repair. Dispose of products contam-
inated with asbestos according to the
applicable country-specific regula-
tions for such disposal.
The current spare parts list for this
vacuum cleaner can be viewed on
the Internet at www.fein.com.
If required, you can change the
following parts yourself:
Fleece filter bag, disposal bag, flat-
fold filter, hose, tool adapter, elbow,
vacuum tubes, crevice nozzle, floor
nozzle, bristle lips, rubber lips, step
adapter, vacuum brushes
Cause
Circuit breaker of
power connection
has tripped.
Vacuum cleaner in
remote control
operation.
Vacuum cleaner not
fitted correctly.
Vacuum system
clogged.
Fleece filter bag full. Replace fleece filter bag.
Flat-fold filter full.
Disposal bag full.
Incorrect installa-
tion position of
flat-fold filter
Troubleshooting
Ensure power supply.
Set operating-mode selector
switch to "I".
Mount vacuum cleaner lid
properly and completely
close both fasteners.
Clean vacuum hose and
extension tubes.
Replace flat-fold filter.
Replace disposal bag.
Correct installation position
of flat-fold filter.

Publicidad

loading

Este manual también es adecuado para:

Dustex 35 mx ac9 20 309 20 32