Zodiac Jandy Pro TruClear Manual De Instalación Y Funcionamiento página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 7
|
Jandy
Pro Series TruClear
Chlorine Generating System
Installation & Operation Manual
ENGLISH
®
WARNING
To minimize risk of severe injury or death, filter, pump, and/or chlorinator should not be subjected to the piping
system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are gener-
ally not intended to apply to the pool equipment, such as filters, pumps, or chlorinators.
Jandy pool equipment is pressure tested at the factory.
If, however, the WARNING cannot be followed and pressure testing of the piping system must include the filter,
pump, and/or chlorinator, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Remove cell and install Pressurizing, Installation and Winterizing Cap (P/N: R0621900) before testing.
• Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly installed and se-
cured before testing.
• RELEASE ALL AIR in the system before testing. AIR PRESSURE must NOT be used for pressure testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C)
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult the equipment
manufacturer.
SAVE THESE INSTRUCTIONS

Publicidad

Tabla de contenido
loading

Tabla de contenido