Field Wiring Guidelines - Daikin Altherna Serie Manual De Instalación

Unidad para bomba de calor de aire-agua
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 141
F3U~F6U ......... Fuse 6.3 A T 250 V
F7U.................. Fuse 5.0 T 250 V
H1P~H7P ........ Orange LED service monitor (A1P)
H2P: prepare, test = flickering
H2P: malfunction detection = light up
HAP (A1P) ....... Green LED service monitor
HAP (A2P) ....... Green LED service monitor
K1M,K2M......... Magnetic contactor
K1R (A1P) ....... Magnetic relay (Y1S)
K1R (A2P) ....... Magnetic relay
K2R (A1P) ....... Magnetic relay (Y2S)
K3R (A1P) ....... Magnetic relay (E1HC)
L1R~L3R ......... Reactor
L4R .................. Reactor for fan motor
M1C ................. Motor (compressor)
M1F ................. Motor (upper fan)
M2F ................. Motor (lower fan)
PS.................... Switching power supply
Q1DI ................ Earth leakage protector
R1~R4 ............. Resistor
R1T.................. Thermistor (air)
R2T.................. Thermistor (discharge)
R3T.................. Thermistor (suction)
R4T.................. Thermistor (heat exchanger)
R5T.................. Thermistor (heat exchanger middle)
R6T.................. Thermistor (liquid)
R7T.................. Thermistor (fin)
S1NPH............. Pressure sensor
S1PH ............... High pressure switch
V1R,V2R.......... Power module
V3R.................. Diode module
X1M ................. (Power supply) terminal strip
X6A,X77A,X1Y ... Optional connectors
Y1E.................. Electronic expansion valve
Y1S.................. Solenoid valve (4 way valve)
Y3S.................. Solenoid valve
Z1C~Z3C ......... Noise filter (ferrite core)
Z1F~Z3F.......... Noise filter
Door 2 electrical parts of the hydraulic compartment
A11P................ Main PCB
A12P................ User interface PCB (remote controller)
A3P.................. Thermostat (EKRTW)(PC=Power Circuit)
A4P.................. Solar/remote alarm PCB (EKRP1HB)
A4P.................. Receiver PCB (EKRTR)
E11H,E12H...... Backup heater element 1, 2 (6 kW)
E13H................ Backup heater element 3 (6 kW)(for W1 models only)
E4H.................. Booster heater (3 kW)
E5H.................. Switch box heater
E6H.................. Expansion vessel heater
E7H.................. Plate heat exchanger heater
F1B .................. Fuse backup heater
F1T .................. Thermal fuse backup heater
F2B .................. Fuse booster heater
F8U,F9U .......... Fuse 1.0 A F 250 V
FU1.................. Fuse 3.15 A T 250 V for PCB
FU2.................. Fuse 5 A T 250 V
FuR,FuS .......... Fuse 5 A 250 V for solar/remote alarm PCB
K1M ................. Contactor backup heater step 1
K3M ................. Contactor booster heater
K4M ................. Pump relay
K5M ................. Contactor for backup heater all pole disconnection
K7M ................. Relay for solar pump
M1P ................. Pump
E(D/B)(H/L)Q011~016AA6V3+W1
Unit for air to water heat pump system
4PW51121-1A
M2S..................2-way valve for cooling mode
M3S..................3-way valve: floor heating/domestic hot water
PHC1 ...............Optocoupler input circuit
Q1DI.................Earth leakage protector
Q1L ..................Thermal protector backup heater
Q2L ..................Thermal protector 1/2 booster heater
Q3L ..................Thermal protector 1/2 booster heater
(for W1 models only)
R1H..................Humidity sensor (EKRTR)
R1T ..................Ambient sensor (EKRTW/EKRTR)
R2T ..................External sensor for floor heating or ambient
temperature (EKRTETS)
R11T ................Outlet water heat exchanger thermistor
R12T ................Outlet water backup heater thermistor
R13T ................Refrigerant liquid side thermistor
R14T ................Inlet water thermistor
R15T ................Domestic hot water thermistor (EKHW*)
S1L...................Flow switch
S1S ..................Solar pumpstation relay
S1T ..................Thermostat switch box heater
S2S ..................Benefit kWh rate power supply contact
S2T ..................Thermostat expansion vessel heater
SS1 ..................DIP switch
TR1 ..................Transformer 24 V for PCB
V1S,V2S ..........Spark suppression 1, 2
X1M-X10M .......Terminal blocks
X2Y ..................Connector

Field wiring guidelines

Most field wiring on the unit is to be made on the terminal block
inside the switch box. To gain access to the terminal block,
remove the switch box service panel (door 2).
Cable tie mountings are provided at the bottom of the switch
box. Fix all cables using cable ties (field supply).
A dedicated power circuit is required for the backup heater.
Installations equipped with a domestic hot water tank (optional),
require a dedicated power circuit for the booster heater.
Please refer to the domestic hot water tank installation manual.
Secure the wiring in the order shown below.
Lay the electrical wiring so that the front cover does not rise up
when doing wiring work and attach the front cover securely(see
figure 2).
Follow the electric wiring diagram for electrical wiring works (the
electric wiring diagrams are located on the rear side of doors 1
and 2).
Form the wires and fix the cover firmly so that the cover may be
fit in properly.
Installation manual
14