Field settings table
First
Second
code
code
Setting name
0
User permission level
00
User permission level
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
01
High ambient temperature (Hi_A)
02
Set point at low ambient temperature (Lo_TI)
03
Set point at high ambient temperature (Hi_TI)
2
Disinfection function
00
Operation interval
01
Status
02
Start time
03
Set point
04
Interval
3
Auto restart
00
Status
4
Backup heater operation and space heating off temperature
00
Status
01
Priority
02
Space heating off temperature
03
Booster heater operation
04
Freeze-up protection function
5
Equilibrium temperature and space heating priority temperature
00
Equilibrium temperature status
01
Equilibrium temperature
02
Space heating priority status
03
Space heating priority temperatures
04
Set point correction for domestic hot water
temperature
6
DT for domestic water heating
00
Start
01
Stop
7
Domestic hot water step length
00
Domestic hot water step length
8
Domestic water heating mode timer
00
Minimum running time
01
Maximum running time
02
Anti-recycling time
03
Booster heater delay time
9
Cooling and heating set point ranges
00
Heating set point upper limit
01
Heating set point lower limit
02
Cooling set point upper limit
03
Cooling set point lower limit
04
Overshoot setting
A
Quiet mode
00
Quiet mode type
01
Parameter 01
E(D/B)(H/L)Q011~016AA6V3+W1
Unit for air to water heat pump system
4PW51121-1A
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
3
2/3
–10
–20~5
15
10~20
40
25~55
25
25~55
Mon~Sun,
Fri
All
1 (ON)
0/1
23:00
0:00~23:00
70
40~80
10
5~60
0 (ON)
0/1
1 (ON)
0/1/2
0 (OFF)
0/1
25
14~25
1
0/1
0 (active)
Read
—
only
1 (ON)
0/1
0
–15~35
0 (OFF)
0/1
0
–15~20
10
0~20
5
1~20
2
2~10
0
0~4
5
0~20
30
5~95
3
0~10
20
20~95
55
37~55
15
15~37
22
18~22
5
5~18
2
1~4
0
0/2
3
—
Step
Unit
1
—
1
°C
1
°C
1
°C
1
°C
—
—
—
—
1:00
hour
5
°C
5
min
—
—
—
—
—
—
1
°C
—
—
—
—
—
—
1
°C
—
—
1
°C
1
°C
1
°C
1
°C
1
°C
1
min
5
min
0.5
hour
5
min
1
°C
1
°C
1
°C
1
°C
1
°C
—
—
—
—
Installation manual
26