Fein Turbo II X Instrucciones De Uso página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000234-002.book Page 7 Tuesday, August 1, 2017 8:47 AM
Do not vacuum materials that are hazardous
to one's health, e. g., dust from beech or oak
wood, masonry dust, asbestos. These materi-
als are considered carcinogenic.
Provide for good ventilation of the workplace.
Do not vacuum inflammable or explosive liq-
uids; for example, gasoline, oil, alcohol, sol-
vents. Do not vacuum hot or inflammable
dusts. Do not operate the machine in rooms
where the danger of an explosion exists. The
dusts, vapors or liquids can ignite or explode.
Do not rivet or screw any name-plates or
signs to the vacuum cleaner. If the insulation
is damaged, protection against an electric
shock will be ineffective. Adhesive labels are
recommended.
Do not use accessories not specifically
intended or recommended for this vacuum
cleaner by FEIN. Just because the accessory
can be attached to your vacuum cleaner, it
does not assure safe operation.
Before putting into operation, check the
power connection and the power plug for
damage.
Emission values for noise and vibrations
(Dual-number values according to IEC 60335-2-69)
Sound emission
A-weighted emission pressure power level measured at
L
the workplace
(re 20 μPa), in decibels
pA
K
Measuring uncertainty
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
Extension cable.
If the use of an extension cable
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
applicational case, in order to prevent a volt-
age drop in the extension cable, power loss
and overheating of the vacuum cleaner. Oth-
erwise, the extension cable and vacuum
cleaner are liable to electrical danger, and the
working efficiency will be impaired.
external power tool. The vacuum cleaner is
automatically put into operation via the con-
nected power tool.
The connected load of the power tool must not
exceed the maximum connected load of the
integrated socket outlet P
Please also observe the operating instruc-
tions and safety warnings of the power tool
being connected to the socket outlet of the
vacuum cleaner.
Recommendation: Always operate the power
tool via a ground-fault circuit interrupter with
a rated residual current of 30 mA or less.
The vacuum cleaner may only be stored
indoors.
The allowable ambient temperature when
vacuuming is +14 °F to +104 °F (–10 °C to
+40 ).
Using the vacuum cleaner at low tempera-
tures is not permitted. At low temperatures,
the mains cable can become damaged and
thus impair the safety.
, in decibels
pA
Use the integrated socket out-
WARNING
let only for connection of an
.
A
Turbo II X
Turbo II X AC HEPA
70
2
en
7
Turbo II X AC /
70
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Turbo ii x acTurbo ii x ac hepa9 20 299 20 30

Tabla de contenido