5. Fitting a pressure gauge

To connect a pressure gauge to the air-driven pump
or oil injector:
Remove the gauge plug.
Screw the pressure gauge irmly into the G
connection assembly.
A T T E N T I O N : Connector B, shown in the next
two illustrations, has left-hand threads!
Adjust the connection assembly until a gap
of approximately 1 mm remains between
connectors A and B.
Screw the complete assembly, including A,
B and the pressure gauge, into the pump or
injector body.
Maintain the 1 mm gap during installation.
When connector A is almost tight, turn the
pressure gauge to the correct position.
Tighten connector A completely.
Do not tighten on connector B.
/