Routing The Electrical Power Supply Leads - Dometic COOLAIR RTX 1000 Instrucciones De Montaje

Ocultar thumbs Ver también para COOLAIR RTX 1000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
RTX1000/2000, SPX1200T
A
NOTICE!
Do not exceed the specified tightening torque under any circumstances. That
is the only way to ensure that the threaded plugs are not pulled out.
➤ Fix the parking cooler in place as illustrated (fig. 0).
7.7

Routing the electrical power supply leads

D
DANGER!
For EX/III and FL vehicles (according to ADR guideline), a battery master switch
must be installed.
!
WARNING!
The electrical connections may only be made by competent technical staff
with the appropriate specialist knowledge.
Before carrying out any work on electrically operated components, make
sure that they are disconnected from the power supply.
A
NOTICE!
The connection to the vehicle's electrical system should be protected by a
40 A fuse for the power supply and a 2 A fuse for the voltage monitor.
The battery must be capable of supplying the required current and voltage
(chapter "Technical data" on page 16).
Connect the unit directly to the main power distribution box.
Ask your vehicle manufacturer for the specifications of the main power
distribution box.
Route the power supply lead as illustrated (fig. a):
➤ Run the wiring loom to the main power distribution box along a route where
it is protected.
➤ Connect the negative lead (black) for the power supply.
➤ Connect the negative lead (black) for the voltage monitor.
➤ Connect the positive lead (red) for the power supply via a 40 A fuse.
➤ Connect the positive lead (red) for the voltage monitor via a 2 A fuse.
➤ Connect the wiring loom to the unit and fix with a cable tie in a suitable
position (fig. a 2.).
EN
Installation
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Coolair rtx 2000Coolair spx 1200tCoolair serieRtx 1000Rtx 2000manSpx 1200t

Tabla de contenido