Dometic COOLAIR SP 950T Instrucciones De Montaje página 18

Juego de montaje para renault trucks con cabina sleeper y high sleeper
Ocultar thumbs Ver también para COOLAIR SP 950T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
Installation
• When installing the system and making the electrical connections, observe
the guidelines from the body manufacturer.
• Pay attention to the connection plan for the device:
No. in
fig. a, page 9
!
WARNING!
Before installing the air conditioning roof unit, all connections to the battery of
the vehicle must be disconnected.
Non-observance of this regulation can result in danger of electrocution.
!
CAUTION!
Improper installation of the air conditioning roof unit can result in irreparable
damage to the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the air conditioning roof
unit is not installed according to this installation manual. That applies to mal-
functions and the safety of the air conditioning roof unit, in particular to injuries
and damage to property.
I
NOTE
After installing the unit, the specified parameters of the unit software must be
checked (chapter "Configuration of unit software" on page 23).
18
Designation
1
Condensate pump
2
Evaporator fan
3
Operating circuit board
4
Temperature sensor
5
Level sensor
6
Control unit
7
25 A fuse
8
4 A fuse vaporiser fan
9
4 A fuse condenser fan
10
Condenser fan
11
Compressor
12
Klickson (compressor)
CoolAir SP950T
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Coolair sp950t

Tabla de contenido