Control unit CP.PONY connections
Except for the mains connection cable, all electric connections
have a voltage of 24V and can also be performed by unquali-
fied staff.
Connect all accessories making reference to the layout in figure
33 and to the "Electric connections" paragraph, for that con-
cerning the types of cable.
To make connection easier, the accessory clamps have colours
that correspond to those of the control unit.
DESCRIPTION OF THE TERMINAL BOARDS
CLAMP
COLOUR
PHOT
GREEN
STOP
BLACK
PP
WHITE
24V
YELLOW
BLINK
RED
SHIELD/ANT
BLUE
A
TX
RX
14
DESCRIPTION
NC input from the RX photocell. The two clamps are connected to each other by a wire (ref. "A").
Remove this wire only if the photocell is connected.
STOP input NC contact for auxiliary "STOP" command (optional). The two clamps are connected to
each other by a wire (ref. "A"). Remove this wire only if a device is connected to this input.
Step-by Step' command input from the key selector. At every impulse sent from the selector a
sequence of commands, which can be configured using the PP function, is performed cyclically.
24Vdc output for photocells power supply. Respect the polarities + and - in the connections (ref "B").
24Vdc flashing light connection output
Connection of the aerial built-in the flashing light.
When connecting the RG58 cable, the external shield must be connected to the SHIELD clamp.
B
BLINK
24V
PP
STOP
PHOT
1
KEY:
1 Line protection fuse
2 Accessories protection fuse
3 "PGM" programming button
4 Programming button "5"
5 LCD
4
2
5
3
Fig.1