Regulation of the automatic closure time (TCA)
The automatic closure function allows to set a time which, on expiry, if the leaf is in the open position the control unit autono-
mously commands a closure manoeuvre.
With this function active, if you forget to give the closure command or in the case of simultaneous commands, the control unit
closes the leaf after the set time.
The factory setting envisions 30 seconds before automatic closure.
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the TCA function is displayed.
Press the [PGM] button to enter the TCA parameter regulation.
The display shows the current value of the TCA parameter.
Use the [5] key to select one of these values:
0
The TCA function is deactivated.
2
1
The pause time is set at 10 seconds (default setting
2
The pause time is set at 30 seconds)
3
The pause time is set at 60 seconds
4
The pause time is set at 90 seconds
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the TCA menu. To exit programming, press the [PGM] and [5] but-
4
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
Regulation of the motor thrust (PMOT)
The force applied is normally set automatically by the control unit during the self-regulation phase (AUTO).
This menu can be used to modify that set by the control unit, to make up for a friction point for example.
Press the [PGM] button to access programming or if the control unit is already in the program-
1
ming menu, press [5] until the PMOT function is displayed.
Press the [PGM] button to enter the PMOT regulation.
The display shows the current value of the PMOT parameter.
Use the [5] key to select one of these values:
2
1
low motors torque
2
medium/low motors torque
3
medium/high motors torque
4
high motors torque (default setting)
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the PMOT menu. To exit programming, press the [PGM] and [5] but-
4
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
16
TCA
0000
0004
PRG
5
PGM+
pmot
PMOT
PMOTPMOT
0001
0004
PRG
5
PGM+