Programming the CP.PONY control unit - Introduction
Programming of the control unit allows the regulation of all
parameters indispensable for the correct functioning of the
automation.
Programming takes place by means of a series of menus that
can be selected from the LCD. A function corresponds to eve-
ry menu, which will be described successively.
The "PGM" button allows to enter programming,
PGM
select the pre-selected menu and confirm the
value selected.
5
The "5" button allows to scroll the various items
in the menu and the values to be set cyclically.
By pressing "5" and "PGM" at the same time,
5
PGM+
return to the upper level of the menu or, if already
at the first level, exit programming.
Self-regulation of the functioning parameters (AUTO)
The first and most important function to program is the self-regulation of the parameters, which allows the control unit to auto-
matically set the end run points, the torque applied to the leaf and the torque in the slowing phase*.
During the autoset operations, the control unit automatically performs several opening and closure manoeuvres.
Before proceeding, check that no person, animal or obstacle is or can be in the door manoeuvre area.
All the accessories provided for the system should be already connected to the control unit. If further accessories should
be added, self-adjustment must be repeated.
Proceed as follows:
1- Apply mains power supply to the automation via the pre-wired socket, using an extension if necessary.
2- Release the leave, take it manually to about half of the run and block it again.
3- Start the autoset phase as described below. As soon as the first manoeuvre starts, carefully check that the leaf moves in the
closure direction.
If this is not the case, press "5" and "PGM" at the same time to interrupt the autoset. The display shows the ERR message. Use
the movement direction reverse button (MINV menu) and change the direction of movement.
1
Press the button [PGM] to access programming.
2
The display shows AUTO, select Auto by pressing the [PGM] button.
AUTO starts to flash slowly. Press and hold the [PGM] key, after 5 seconds AUTO starts to flash
3
quickly, release the key only when the display shows the PRG message.
The self-regulation phase starts, the display shows PRG. The control unit commands different
4
opening and closing manoeuvres at various speeds.
At the end of the manoeuvre the display shows "OK"
The control unit goes back to the AUTO menu. To exit programming, press the [PGM] and [5] but-
5
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
* The slowing phase must be activated via the TSM parameter. The control unit is supplied with the parameter set at 0 (Off); the
AUTO function does not activate slowing but is limited to defining a suitable torque value.
The intervention of the photocells or any other command from the transmitter or key selector, interrupts the autoset
phase, displaying the message ERR1/2/3. The procedure must therefore be repeated.
Every self-regulation procedure overwrites the previous one.
Perform an autostop procedure after every maintenance intervention or modification of the door.
LCD
With the display off, the "5" button performs a Step-
by-Step command. This function can be useful during
the programming and inspection phases.
Pressing the PGM button causes the immediate stop
of any leaf movement.
PGM
PGM
AUTO
PRG
5
PGM+
15