Regulation of the slowing time (TSM)
If the leaf is to slow for a few seconds before the end run intervention, select one of the values available, as described below.
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the TSM function is displayed.
Press the [PGM] button to enter the TSM regulation.
The display shows the current value of the TSM parameter.
Use the [5] key to select one of these values:
0
Slowing not active (default setting)
2
1
3 slowing seconds
2
5 slowing seconds
3
7 slowing seconds
4
10 slowing seconds
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the TSM menu. To exit programming, press the [PGM] and [5] but-
4
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
After every modification of the value of this parameter, it is necessary to proceed with a new self-learning phase
Step-by-Step functioning mode (PP)
It is possible to select two different modes of the Step-by Step command sent from the transmitter or the key selector.
Every time the button is pressed in the default mode, the following progression of commands is performed cyclically:
OPEN>STOP>CLOSE>STOP>OPEN> and so on.
The sequence can be modified by eliminating the intermediate STOP commands: OPEN>CLOSE>OPEN> and so on.
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the PP function is displayed.
Press the [PGM] button to enter the PP regulation.
The display shows the current value of the PP parameter.
2
Use the [5] key to select one of these values:
ON
OPEN>CLOSE>OPEN functioning (default)
OFF
OPEN>STOP>CLOSE>STOP>OPEN> functioning
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the PP menu. To exit programming, press the [PGM] and [5] buttons
4
at the same time or, alternatively, remove the power supply or wait 60 seconds.
Pre-flashing functioning mode (Pre)
An imminent manoeuvre warning mode can be set through the pre-flashing function.
Once activated, the flashing light switches on 3 seconds before the door starts to move.
Press the [PGM] button to access programming or if the control unit is already in the programming
1
menu, press [5] until the Pre function is displayed.
Press the [PGM] button to enter the Pre regulation.
The display shows the current value of the Pre parameter.
2
ON
pre-flashing activated
OFF
pre-flashing deactivated (default)
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the PRE menu. To exit programming, press the [PGM] and [5] but-
4
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
TSM
PMOT
PMOTPMOT
0000
0004
PRG
5
PGM+
PP
PMOT
on
off
PRG
5
PGM+
Pre
PMOT
on
off
PRG
5
PGM+
17