Replacement Of Pump Oil - Orved Evox 31 Hi-Line Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

15.3 Replacement of pump oil

1) Run the pump for about 10 minutes until the oil is fluid, with the
appliance in Jar mode (press the PUMP key).
2) Stop the pump by pressing the STOP key.
3) Turn the appliance off using the ON/OFF switch and disconnect
the plug from the mains.
4) Remove the PE fillers from the vacuum chamber (Fig. 8).
5) Remove the back panel, unscrewing the screws using an Allen
wrench (Fig. 9-10-11).
6) Lift the casing with both hands and open it by about 45°. Lock the
casing in place using the special rod (A) (Fig. 12).
evox
31
Rev. 02 - 06/2018 - Cod. 1500339 - Vacuum packaging machine user manual
Hi-Line
Fig. 9
Fig. 10
A
45°
Fig. 12
MAINTENANCE
Fig. 8
Fig. 11