Electrical and Fuel Inlet Locations
The 3/4 inch N.P.T. fuel inlet connector (A) and electrical
inlet location (B) are shown below.
The home generator is shipped already attached to its
mounting pad. Unless mandated by local code, a concrete
slab is not required.
A
B
Lifting the Generator
WARNING Hazardous Voltage - Contact with power
lines could cause electric shock or burns,
resulting in death or serious injury.
Lifting Hazard / Heavy Object - Could result
in serious injury.
If lifting or hoisting equipment is used, DO NOT contact
any power lines.
DO NOT lift or move generator without assistance.
Use lifting pipes as described in Lifting the Generator.
DO NOT lift unit by roof as damage to generator
will occur.
The generator has a shipping weight of approximately 605
pounds (274 kg). Proper tools, equipment and qualified
personnel should be used in all phases of handling and
moving the generator.
required to lift the generator manually. Insert pipes through
the lifting holes (D) located near the unit's base.
attached to the lifting pipes, provided that you use a spreader
pes, provid
s, provid
bar to ensure that the chains or cables DO NOT touch the
chains or ca
chains or
generator's roof.
After unit is in place, fill the lifting holes with the supplied
place, fill the
place, fill t
lifting hole plugs.
plugs
plugs.