Rothenberger ROWELD ROFUSE Turbo Instrucciones De Uso página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
button and therefore remains empty. If the option "Traceability of fittings" is deactivated, it will
not be displayed on the screen and not queried.
Now connect the welding contacts with the fitting. Use a suitable adapter if necessary (see Sec-
tion 5). The contact surfaces of the welding plug or adapter and the fitting must be clean.
Scan in the scan fitting code with the aid of the barcode scanner. If the barcode scanner is de-
fective or if the scan fitting code cannot be read in, the scan fitting code can also be entered
manually. To do this press the >KEYBOARD< button (see also Section "Data entry").
If there is no cooling time integrated in the bar code of the fitting, the cooling time which is writ-
ten on the fitting can be entered manually. The user can skip this entry by pressing the >OK<
button.
If there is a cooling time integrated in the bar code of the fitting, this cooling time is shown in the
display after the welding process is finished. The cooling time count down is running and the
cooling time is recorded.
If there is no cooling time integrated in the bar code of the fitting and the user has manually en-
tered the cooling time, this time is shown in the display after the welding process is finished. The
cooling time count down is running but the cooling time is not recorded.
Cooling Time
If there is no barcode integrated in the fitting and the user has not entered manually, the cooling
time is not shown in the display and it will not be recorded.
After successful data entry the screen changes to the query concerning whether the pipes are
machined according to manufacturer's instructions. This must be confirmed with >OK<.
Before the actual welding starts the device again displays all relevant welding parameters.
Diameter ............ Pipe diameter according to the scan fitting code
Energy ............... Energy used
24
ENGLISH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

10000009991000001000Rofuse 400 turboRofuse 1200 turbo

Tabla de contenido