CAMPAGNOLO Ergobrain Manual De Uso página 7

Ocultar thumbs Ver también para Ergobrain:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Resin cover
Interface sensor
Rotary-ring
OK
Button
Interface sensor
Insert the switch button
as figure shows.
- 3
UK
are connected to the bracket.) Then install the
bracket to the center of your handlebar.
If your bicycle already has the Ergopower le-
vers, you need to detach them according to the
instruction.
*) Whether to install the CDC sensor or not, is
your choice.
Interface Sensor
Note: Tiny parts are included. Be careful not to
lose them.
Note: Some parts are specified for right side
and left side. Be careful not to install them
in the reverse way.
DANGER !
Keep all parts out of the reach of children.
1. Shift to the lowest gear.
2. Detach the Ergopower lever using a 5mm
allen key.
3. Remove the resin cover located at the bot-
tom of the body.
4. Carefully insert the interface sensor into the
lever, pushing gently on the main part of the
insert and on the upper appendix at the same
time, paying also attention to the right and
the left**.
Note that the position of the rotary-ring
should be as illustrated.
**) The interface sensor with the black ro-
tary-ring is for the left lever, the interface
NO!
sensor with the white ring (9s) or the red ring
(10s) are for the right lever.
5. Install the switch button onto the lever as il-
lustrated. "DX" is for the right lever and "SX"
for the left. In case you have installed it to
the wrong side, do not pull it out forcibly, but
remove the interface sensor first and push
the button inward.
6. Reinstall the Ergopower lever to your han-
dlebar.
Refer to the instruction manual of the Ergopower
for how to install and detach the Ergopower lever,
as well as for how to adjust the cable.
How to Remove Interface Sensor
Remove the interface sensor, then push the
button inward.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ergobrain10

Tabla de contenido