When length of an offset is negative, maxi-
mum fastener target is limited by following
formulas:
· 240 in-lb wrench:
Maximum Target Torque = offset * 24 + 240
Offset
-1"
-2"
-3"
-4"
· 100 ft-lb wrench:
Maximum Target Torque = offset * 7 + 100
Offset
-1"
-2"
-3"
-4"
· 250 ft-lb wrench:
Maximum Target Torque = offset * 11 + 250
Offset
-1"
-2"
-3"
-4"
· 600 ft-lb wrench:
Maximum Target Torque = offset * 14 + 600
Offset
-1"
-2"
-3"
-4"
-1"
NOTE: When using a negative offset, entering
a target torque greater than maximum values
above may cause an over-torque error before
reaching fastener target torque and possibly
damage wrench.
24
Max Target
216 in-lb
192 in-lb
168 in-lb
144 in-lb
Max Target
93 ft-lb
86 ft-lb
79 ft-lb
72 ft-lb
Max Target
239 ft-lb
228 ft-lb
217 ft-lb
206 ft-lb
Max Target
586 ft-lb
572 ft-lb
558 ft-lb
544 ft-lb
586 ft-lb
VIEWING STORED TORQUE AND ANGLE
DATA
Torque data is stored in memory after each
torque cycle if applied torque has reached tar-
get value. Torque and angle data is stored in
memory after each angle cycle if applied angle
has reached target value. Memory Indicator is
displayed when data is stored in non-volatile
memory.
1. To view stored torque and angle data, from
target torque or angle screen, press and hold
ENTER button for 3 seconds. 2. Highlight
SHOW DATA menu selection by pressing UP/
DOWN buttons then press ENTER button to
display Show Data screen.
3. In Show Data screen, scroll through each
stored data record by pressing UP/DOWN but-
tons.
Example: 0002 = Show Data List Counter: TQ =
Peak torque value
0001 = Show Data List Counter: TQ = Peak
torque value: ANG = Peak angle value
4. Pressing ENTER button while on Show Data
screen returns to main menu.
NOTE: A maximum of 1500 data records can
be stored in memory. Memory full icon will be
displayed when full and no more data is stored
until memory is cleared.
DELETING STORED TORQUE AND ANGLE
DATA
1. From target torque or angle screen, press
and hold ENTER button for 3 seconds. 2. High-
light CLEAR DATA menu selection using UP/
If clock has been set data
timestamp will be displayed
(see Advanced Configuration).