2. Angle target screen is displayed. Use UP/
DOWN buttons to set target angle then press
ENTER button.
3. Torque THEN Angle mode screen is dis-
played.
4. Apply torque until target is reached then ro-
tate wrench to target angle.
NOTE: UNITS button can
be used to select torque
units while on Torque
THEN Angle screen.
NOTE: Torque cycle is not recorded in memory
unless both torque and angle reach targets.
Note: Red progress lights turn on if torque ex-
ceeds 110% of wrench full scale or if angle ex-
ceeds target + plus tolerance while in manual
mode.
NOTE: Torque THEN Angle Presets are entered
by pressing and holding Units button while
on Torque THEN Angle screen. MAXIMUM
TORQUE defaults to full range plus 10%. Refer
to "Adding a Torque Preset" and "Adding an
Angle Preset" in Basic section for parameter
entry.
ENABLE/DISABLE
MODE
This function will allow user to enable or dis-
able Torque AND Mode. 1. From Mode Setup
menu, use UP/DOWN buttons to highlight AND
DISABLED (factory default) selection then press
ENTER button.
2. TQ AND ANGLE enable/disable screen is dis-
played.
3. Use UP/DOWN buttons to select ENABLE or
DISABLE selection.
4. Press ENTER button to accept selection and
exit to Mode Setup menu.
NOTE: Menu selection indicates current con-
figuration (ENABLED or DISABLED).
TORQUE AND ANGLE MODE
Torque AND Angle mode is setup by first set-
ting a target torque and units then a target an-
gle before selecting Torque AND Angle mode.
30
TORQUE
AND
ANGLE
In Torque AND Angle mode, torque and angle
are measured simultaneously. Yellow progress
lights track torque measurement. When both
torque and angle reach their targets, green
progress lights turn on and torque and angle
data record is stored. If either of measure-
ments exceed their upper tolerance, red prog-
ress lights turn on.
1. From target torque screen, use UP/DOWN
buttons to set target torque and UNITS button
to select torque measurement units then press
ENTER button.
2. Angle target screen is displayed. Use UP/
DOWN buttons to set target angle then press
ENTER button until Torque AND Angle mode
screen is displayed.
3. Apply torque and rotate wrench until both
targets are reached.
NOTE: UNITS button can be used to select
torque units while on Torque AND Angle
screen.
NOTE: Torque THEN Angle Presets are entered
by pressing and holding Units button while on
Torque THEN Angle screen. Refer to "Adding a
Torque Preset" and "Adding an Angle Preset"
in Basic section for parameter entry.
NOTE: Torque cycle is not recorded in memory
unless both torque and angle reach targets.
NOTE: Red progress lights turn on if torque
exceeds target + plus tolerance or if angle ex-
ceeds target + plus tolerance while in manual
mode.
NOTE: Red progress lights turn on if torque
exceeds maximum torque or if angle exceeds
maximum angle in Preset mode.
PRESET LOCK
Preset Lock function allows user to lock wrench
so that only configured presets are accessible.
No other presets can be configured and man-
ual target torque and angle modes are not ac-
cessible when locked.
NOTE: When Preset Lock is enabled, password
entry is required to re-enter Configure menu
(Contact URREA Repair Center regarding Con-
figure password).
1. From Configure menu, use UP/DOWN but-
tons to highlight PRESET LOCK selection then
press ENTER button.
2. Preset Lock enable/disable screen is dis-
played.