NOTE: When date and time is set for first time,
In-Service date is also set and is used for calcu-
lating initial calibration interval (see "Setting
Calibration Interval" in Advanced Configura-
tion section).
TORQUE MODE
1. Set Target. Use UP/DOWN buttons to change
TORQUE target value.
2. Select Units of Measure. Repeatedly press
UNITS button while on target TORQUE screen
until desired units are displayed.
3. Apply TORQUE. Grasp center of handle, (DO
NOT pull on battery end-cap) and slowly apply
torque to fastener until progress lights display
green and a ½ second audible alert and handle
vibration alerts you to stop.
4. Release TORQUE. Note peak TORQUE read-
ing flashing on LCD display for 5 seconds.
Pressing BACKLIGHT button while peak torque
is flashing will continue to display value until
button is released. Momentarily pressing UP/
DOWN, ENTER or UNITS button will immedi-
ately return to target TORQUE screen. Reap-
plying TORQUE will immediately start another
TORQUE measurement cycle.
5. Recall Peak TORQUE Reading. To recall last
peak TORQUE measurement, press and hold
BACKLIGHT button for approximately 3 sec-
onds. Peak TORQUE will flash for 5 seconds.
22
ANGLE MODE
1. Set target. Use UP/DOWN buttons to change
target ANGLE value. 2. Apply Torque and Ro-
tate Wrench.
Grasp center of handle, (DO NOT pull on bat-
tery end-cap) and slowly apply torque to fas-
tener and rotate wrench at a moderate consis-
tent speed until progress lights display green
and a ½ second audible alert and handle vibra-
tion alerts you to stop.
3. Release torque. Note alternating peak
TORQUE and ANGLE readings flashing on LCD
display for 5 seconds. Pressing BACKLIGHT but-
ton while peak values are flashing will con-
tinue to display values until button is released.
Momentarily pressing UP/DOWN, ENTER or
UNITS button will immediately return to target
ANGLE screen. Reapplying torque (ratcheting)
before target screen is displayed will continue
ANGLE accumulation as wrench is rotated.
4. Recall Peak ANGLE Reading. To recall last
peak ANGLE measurement, press and hold
BACKLIGHT button for approximately 3 sec-
onds. Peak TORQUE and ANGLE will be dis-
played alternately for 5 seconds.
MODE CYCLE COUNT
Computorq mode cycle count feature is used to
indicate number of times wrench has reached
target torque in torque measurement mode or
target angle in angle measurement mode.
MEMORY
ICON
TORQUE AND ANGLE MODE CYCLE COUNTING
1. Numerical counter located in top right of
target torque or target angle screen will incre-
ment after each torque or angle cycle if ap-
plied torque or angle has reached target value.
2. When toggling between torque mode or
angle mode using ENTER button or if target is
changed, numerical counter will reset back to
00. Counter WILL NOT reset when re-zeroing,
on menu entry/exit or power down.
3. Memory icon will turn on indicating at least
one torque or angle cycle data has been stored
in memory.
DATA DOWNLOAD
Torque and Angle data in memory can be
downloaded to a computer via USB port.
MODE CYCLE
COUNT