MAINTENANCE
Clean wrench by wiping with a damp cloth. DO
NOT use solvents, thinners or carburetor clean-
ers. DO NOT immerse in anything. Service and
repairs are to be done by URREA Service Cen-
ter only. Contact your URREA Torque Products
representative.
Ratchet head repair kits can be ordered from a
URREA Representative.
NOTES: If display shows persistent "TORQUE
ZERO ERROR" at power on, wrench is damaged
and must be returned for repair
- If display shows "ANGLE ERROR" in angle
mode, fastener rotation speed has exceeded
capacity of wrench.
- Wrench must be held still during angle zero-
ing. Motion is indicated by alternating dashes
"- -" on display
- Remove battery when stored for extended
periods (Note: clock will revert to default set-
tings).
BATTERY REPLACEMENT
NOTE: When replacing batteries, real-time-
clock will maintain date and time for 20 min-
utes.
NOTE: Turn End Cap counter-clockwise to un-
screw.
REPLACE 6205 MODELS WITH THREE LITHIUM
"AAA" CELLS ONLY.
Batteries should be installed in carrier prior to
carrier installation into wrench.
Battery negative contacts should be oriented
with carrier springs.
Replace all other models with three Lithium
"AA" cells only.
NOTE: When Replace Battery screen is dis-
played wrench will no longer operate until
batteries are replaced. Only POWER button
functions which immediately turns off wrench.
E N G L I S H •
MEMORY INDICATORS
DATA IN MEMORY
Less than 1500 torque and angle records
stored in memory.
MEMORY FULL
1500 torque or angle records stored in
memory. New records will not be record-
ed until memory is cleared.
MEMORY ERROR
Memory read or write error. Return to
Factory if occurs.
TROUBLESHOOTING
NOTE: If any of following issues persist, return
wrench to URREA repair center.
WRENCH DOES NOT TURN ON WHEN POWER
BUTTON PRESSED
Dead/No batteries: Replace batteries.
Software glitch: Cycle power using end-cap.
TORQUE READING OUT OF SPEC
Calibration required: Recalibrate.
Incorrect head length entered: Enter correct
offset head length.
WRENCH DID NOT RETAIN SETTINGS WHILE
BATTERIES WERE REMOVED
Batteries removed before setting were saved
in non-volatile memory: Clear data, re-enter
settings and press and hold POWER button to
power down wrench before removing batter-
ies.
Low
ENTER button to contin-
ue using wrench and re-
place batteries soon.
Dead
POWER button to turn
off wrench and replace
batteries.
U se r's m a n ua l
battery:
Press
battery:
Press
33